Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,304
matching recommendationsNAICS | 3329 | Other Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0243 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,277 | $2,030 | Implemented |
BD0243 # 09 Y:2003 | 09 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,840 | $0 | Implemented |
BD0243 # 10 Y:2003 | 10 | 2003 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,838 | $2,460 | Implemented |
BD0243 # 11 Y:2003 | 11 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $816 | $185 | Not Implemented |
BD0243 # 12 Y:2003 | 12 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $567 | $500 | Not Implemented |
BD0243 # 13 Y:2003 | 13 | 2003 | USE PHOTOCELL CONTROLS | $168 | $500 | Not Implemented |
BD0243 # 14 Y:2003 | 14 | 2003 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,772 | $5,500 | Not Implemented |
BD0243 # 15 Y:2003 | 15 | 2003 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,305 | $4,243 | Not Implemented |
BD0243 # 16 Y:2003 | 16 | 2003 | MODIFY WORKLOAD | $186,751 | $10,000 | Not Implemented |
BD0243 # 17 Y:2003 | 17 | 2003 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $49,200 | $1,000 | Implemented |
BD0243 # 18 Y:2003 | 18 | 2003 | PAY BILLS ON TIME TO AVOID LATE FEES | $320 | $0 | Not Implemented |
SU0166 # 01 Y:2003 | 01 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,012 | $232 | Not Implemented |
SU0166 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,388 | $480 | Not Implemented |
SU0166 # 03 Y:2003 | 03 | 2003 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $28,125 | $10,016 | Implemented |
SU0166 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,270 | $24,797 | Not Implemented |
SU0166 # 05 Y:2003 | 05 | 2003 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $24,000 | $19,912 | Not Implemented |
SU0166 # 06 Y:2003 | 06 | 2003 | USE EXISTING DAM TO GENERATE ELECTRICITY | $49,025 | $132,000 | Not Implemented |
SU0166 # 07 Y:2003 | 07 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,000 | $68,560 | Implemented |
LE0170 # 01 Y:2003 | 01 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $210,423 | $300,000 | Not Implemented |
LE0170 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,647 | $7,000 | Implemented |
LE0170 # 03 Y:2003 | 03 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $952 | $0 | Implemented |
LE0170 # 04 Y:2003 | 04 | 2003 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $367 | $0 | Implemented |
LE0170 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $440 | $560 | Not Implemented |
LE0170 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $425 | $825 | Not Implemented |
UU0053 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,354 | $4,100 | Not Implemented |