Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
41
matching recommendationsNAICS | 3329 | Other Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0927 # 02 Y:2015 | 02 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $21,107 | $133,275 | Implemented |
OK0927 # 01 Y:2015 | 01 | 2015 | COMBINE UTILITY METERS | $19,646 | $14,000 | Not Implemented |
OK0890 # 06 Y:2014 | 06 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,700 | $0 | Implemented |
OK0890 # 01 Y:2014 | 01 | 2014 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $9,580 | $770 | Not Implemented |
OK0890 # 03 Y:2014 | 03 | 2014 | INSTALL COMMON HEADER ON COMPRESSORS | $1,460 | $1,200 | Not Implemented |
OK0890 # 04 Y:2014 | 04 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,200 | $0 | Implemented |
OK0890 # 02 Y:2014 | 02 | 2014 | INSTALL COMMON HEADER ON COMPRESSORS | $8,687 | $4,800 | Implemented |
OK0890 # 07 Y:2014 | 07 | 2014 | USE MINIMUM SAFE OVEN VENTILATION | $30,394 | $1,000 | Implemented |
OK0890 # 05 Y:2014 | 05 | 2014 | AIR CONDITION ONLY SPACE NECESSARY | $6,400 | $1,230 | Implemented |
OK0851 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,912 | $6,000 | Not Implemented |
OK0851 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,232 | $14,940 | Not Implemented |
OK0851 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,400 | $1,900 | Implemented |
OK0851 # 05 Y:2013 | 05 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,400 | $44,200 | Implemented |
OK0851 # 01 Y:2013 | 01 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,442 | $0 | Not Implemented |
OK0851 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $647 | $1,132 | Not Implemented |
OK0844 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,922 | $21,000 | Implemented |
OK0844 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,000 | $32,130 | Not Implemented |
OK0844 # 03 Y:2013 | 03 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $11,299 | $76,750 | Implemented |
OK0844 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,154 | $4,200 | Implemented |
OK0844 # 05 Y:2013 | 05 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,800 | $18,500 | Not Implemented |
TT0063 # 07 Y:2011 | 07 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,424 | $120 | Not Implemented |
TT0063 # 06 Y:2011 | 06 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $12,516 | $4,000 | Not Implemented |
TT0063 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $8,057 | $30,500 | Not Implemented |
TT0063 # 04 Y:2011 | 04 | 2011 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $900 | $1,050 | Implemented |
TT0063 # 03 Y:2011 | 03 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,238 | $0 | Not Implemented |