Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsNAICS | 33291 | Metal Valve Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0522 # 06 Y:2016 | 06 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,109 | $1,101 | Implemented |
SD0522 # 01 Y:2016 | 01 | 2016 | USE SOLAR HEAT TO MAKE ELECTRICTY | $96,572 | $386,410 | Implemented |
SD0522 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,917 | $200 | Implemented |
SD0522 # 02 Y:2016 | 02 | 2016 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $31,891 | $46,500 | Not Implemented |
SD0522 # 04 Y:2016 | 04 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,220 | $21,500 | Not Implemented |
SD0522 # 05 Y:2016 | 05 | 2016 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $8,454 | $1,725 | Implemented |
SD0522 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,341 | $22,524 | Implemented |
SD0517 # 08 Y:2015 | 08 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $736 | $2,350 | Not Implemented |
SD0517 # 07 Y:2015 | 07 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,154 | $2,000 | Implemented |
SD0517 # 06 Y:2015 | 06 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,975 | $9,935 | Not Implemented |
SD0517 # 05 Y:2015 | 05 | 2015 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $5,974 | $8,760 | Not Implemented |
SD0517 # 04 Y:2015 | 04 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $18,457 | $11,700 | Implemented |
SD0517 # 03 Y:2015 | 03 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $54,235 | $108,000 | Not Implemented |
SD0517 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $54,474 | $5,633 | Not Implemented |
SD0517 # 01 Y:2015 | 01 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $69,718 | $163,200 | Implemented |
SD0512 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $3,224 | $2,850 | Implemented |
SD0512 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,985 | $5,247 | Implemented |
SD0512 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,532 | $800 | Implemented |
SD0512 # 03 Y:2015 | 03 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,185 | $45,900 | Implemented |
SD0512 # 02 Y:2015 | 02 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,697 | $25,608 | Implemented |
SD0512 # 01 Y:2015 | 01 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $34,138 | $61,820 | Not Implemented |
SD0442 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $597 | $1,566 | Not Implemented |
SD0442 # 05 Y:2011 | 05 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,760 | $26,500 | Not Implemented |
SD0442 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,100 | $100 | Not Implemented |
SD0442 # 01 Y:2011 | 01 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $727 | $100 | Not Implemented |