IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

897

matching recommendations
Reset
NAICS 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0906 # 03 Y:2015 03 2015 USE PHOTOCELL CONTROLS $1,977 $2,220 Not Implemented
OK0906 # 04 Y:2015 04 2015 INSTALL OCCUPANCY SENSORS $276 $1,202 Not Implemented
OK0906 # 05 Y:2015 05 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $727 $2,651 Not Implemented
OK0906 # 06 Y:2015 06 2015 INSTALL TIMERS AND/OR THERMOSTATS $1,362 $0 Not Implemented
OK0906 # 07 Y:2015 07 2015 USE RADIANT HEATER FOR SPOT HEATING $3,385 $15,625 Not Implemented
OK0906 # 08 Y:2015 08 2015 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $3,154 $10,516 Not Implemented
OK0906 # 09 Y:2015 09 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $201 $476 Not Implemented
LE0380 # 01 Y:2014 01 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $19,389 $780 Not Implemented
LE0380 # 02 Y:2014 02 2014 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,774 $800 Not Implemented
LE0380 # 03 Y:2014 03 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $593 $520 Not Implemented
LE0380 # 04 Y:2014 04 2014 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,824 $2,960 Not Implemented
LE0380 # 05 Y:2014 05 2014 RECOVER WASTE HEAT FROM EQUIPMENT $938 $1,936 Not Implemented
LE0380 # 06 Y:2014 06 2014 USE RADIANT HEATER FOR SPOT HEATING $22,320 $54,000 Not Implemented
LE0380 # 07 Y:2014 07 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,916 $5,000 Not Implemented
LE0380 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,740 $4,950 Not Implemented
LE0380 # 09 Y:2014 09 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $607 $2,000 Not Implemented
OK0890 # 01 Y:2014 01 2014 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $9,580 $770 Not Implemented
OK0890 # 02 Y:2014 02 2014 INSTALL COMMON HEADER ON COMPRESSORS $8,687 $4,800 Implemented
OK0890 # 03 Y:2014 03 2014 INSTALL COMMON HEADER ON COMPRESSORS $1,460 $1,200 Not Implemented
OK0890 # 04 Y:2014 04 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $1,200 $0 Implemented
OK0890 # 05 Y:2014 05 2014 AIR CONDITION ONLY SPACE NECESSARY $6,400 $1,230 Implemented
OK0890 # 06 Y:2014 06 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,700 $0 Implemented
OK0890 # 07 Y:2014 07 2014 USE MINIMUM SAFE OVEN VENTILATION $30,394 $1,000 Implemented
BS0034 # 01 Y:2014 01 2014 OPTIMIZE PLANT POWER FACTOR $10,406 $20,000 Not Implemented
BS0034 # 02 Y:2014 02 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $74,212 $31,860 Not Implemented