Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
69
matching recommendationsNAICS | 332999 | All Other Miscellaneous Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0527 # 01 Y:2016 | 01 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $13,053 | $54,000 | Not Implemented |
WV0527 # 09 Y:2016 | 09 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $581 | $1,275 | Implemented |
WV0527 # 07 Y:2016 | 07 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,189 | $283 | Not Implemented |
WV0527 # 05 Y:2016 | 05 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $2,540 | $4,500 | Not Implemented |
WV0527 # 10 Y:2016 | 10 | 2016 | INSULATE BARE EQUIPMENT | $252 | $263 | Implemented |
WV0527 # 08 Y:2016 | 08 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,044 | $165 | Implemented |
WV0527 # 04 Y:2016 | 04 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,255 | $6,300 | Not Implemented |
WV0527 # 11 Y:2016 | 11 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $212 | $527 | Implemented |
WV0527 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,268 | $2,530 | Implemented |
WV0527 # 02 Y:2016 | 02 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,539 | $1,100 | Implemented |
UD0927 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,206 | $1,000 | Not Implemented |
UD0927 # 07 Y:2015 | 07 | 2015 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $11,280 | $0 | Not Implemented |
UD0927 # 06 Y:2015 | 06 | 2015 | COMBINE UTILITY METERS | $63,547 | $50,000 | Not Implemented |
UD0927 # 05 Y:2015 | 05 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,750 | $3,000 | Not Implemented |
UD0927 # 04 Y:2015 | 04 | 2015 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $11,905 | $0 | Not Implemented |
UD0927 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,022 | $300 | Implemented |
UD0927 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,025 | $0 | Implemented |
UD0802 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $797 | $1,907 | Implemented |
UD0802 # 07 Y:2009 | 07 | 2009 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,084 | $2,812 | Not Implemented |
UD0802 # 06 Y:2009 | 06 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,230 | $1,500 | Implemented |
UD0802 # 05 Y:2009 | 05 | 2009 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,711 | $6,468 | Not Implemented |
UD0802 # 04 Y:2009 | 04 | 2009 | INSTALL AUTOMATIC STACK DAMPER | $3,637 | $1,000 | Not Implemented |
UD0802 # 03 Y:2009 | 03 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,645 | $0 | Implemented |
UD0802 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $2,374 | Implemented |
UD0802 # 10 Y:2009 | 10 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,334 | $1,000 | Implemented |