Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
364
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0199 # 06 Y:2010 | 06 | 2010 | INSULATE BARE EQUIPMENT | $8,626 | $1,786 | Not Implemented |
MI0199 # 05 Y:2010 | 05 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,954 | $2,200 | Implemented |
MI0199 # 04 Y:2010 | 04 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $10,308 | $7,450 | Implemented |
MI0199 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,329 | $1,210 | Implemented |
MI0199 # 01 Y:2010 | 01 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $37,073 | $6,280 | Implemented |
MI0199 # 08 Y:2010 | 08 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $4,552 | $4,531 | Implemented |
MI0178 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $88,417 | $70,875 | Not Implemented |
MI0178 # 02 Y:2009 | 02 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $53,553 | $7,140 | Implemented |
MI0178 # 03 Y:2009 | 03 | 2009 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $18,854 | $40,320 | Not Implemented |
MI0178 # 04 Y:2009 | 04 | 2009 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $17,481 | $11,118 | Not Implemented |
MI0178 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,720 | $1,210 | Implemented |
MI0178 # 06 Y:2009 | 06 | 2009 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,908 | $4,531 | Implemented |
MI0178 # 07 Y:2009 | 07 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,282 | $40 | Implemented |
UF0411 # 01 Y:2008 | 01 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,719 | $4,557 | Not Implemented |
UF0411 # 02 Y:2008 | 02 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $47,620 | $6,301 | Not Implemented |
UF0411 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,287 | $40,292 | Implemented |
UF0411 # 04 Y:2008 | 04 | 2008 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $3,258 | $461 | Implemented |
UF0411 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $1,200 | $215 | Implemented |
UF0411 # 06 Y:2008 | 06 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $888 | $364 | Not Implemented |
UF0411 # 07 Y:2008 | 07 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $62,348 | $20,000 | Not Implemented |
UF0411 # 08 Y:2008 | 08 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,520 | $1,000 | Not Implemented |
UF0411 # 09 Y:2008 | 09 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $53,144 | $426 | Implemented |
UF0411 # 10 Y:2008 | 10 | 2008 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,946 | $25,280 | Not Implemented |
UF0411 # 11 Y:2008 | 11 | 2008 | MODIFY WORKLOAD | $8,002 | $0 | Not Implemented |
UF0411 # 12 Y:2008 | 12 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,419 | $3,400 | Not Implemented |