Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0157 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,149 | $30,133 | Implemented |
MZ0157 # 04 Y:2014 | 04 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $2,223 | $17,400 | Not Implemented |
MZ0157 # 05 Y:2014 | 05 | 2014 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $3,840 | $9,600 | Implemented |
OK0896 # 01 Y:2014 | 01 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,242 | $1,588 | Not Implemented |
OK0896 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,653 | $1,751 | Implemented |
OK0896 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,702 | $400 | Implemented |
OK0896 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,435 | $16,592 | Not Implemented |
OK0896 # 05 Y:2014 | 05 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,020 | $43,252 | Not Implemented |
OK0896 # 06 Y:2014 | 06 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $13,523 | $7,700 | Not Implemented |
OK0896 # 07 Y:2014 | 07 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $746 | $169 | Implemented |
OK0896 # 08 Y:2014 | 08 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,458 | $28,800 | Not Implemented |
OK0896 # 09 Y:2014 | 09 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,826 | $9,200 | Not Implemented |
NC0524 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,264 | $42,866 | Implemented |
NC0524 # 02 Y:2014 | 02 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $19,056 | $100 | Implemented |
NC0524 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,368 | $100 | Implemented |
NC0524 # 04 Y:2014 | 04 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $7,341 | $29,000 | Not Implemented |
NC0524 # 05 Y:2014 | 05 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $606 | $300 | Implemented |
NC0524 # 06 Y:2014 | 06 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,243 | $475 | Implemented |
NC0524 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,355 | $3,984 | Implemented |
NC0524 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $1,948 | $3,644 | Implemented |
NC0524 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $550 | $160 | Implemented |
NC0524 # 10 Y:2014 | 10 | 2014 | USE PHOTOCELL CONTROLS | $54 | $40 | Implemented |
NC0524 # 11 Y:2014 | 11 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $1,126 | $1,050 | Implemented |
NC0524 # 12 Y:2014 | 12 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $2,718 | $8,146 | Implemented |
NC0524 # 13 Y:2014 | 13 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $818 | $180 | Implemented |