Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0004 # 04 Y:2012 | 04 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $21,686 | $18,150 | Implemented |
IP0004 # 05 Y:2012 | 05 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,462 | $15,867 | Not Implemented |
IP0004 # 06 Y:2012 | 06 | 2012 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $10,500 | $27,000 | Not Implemented |
MAS029 # 01 Y:2012 | 01 | 2012 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $13,149 | $500 | Implemented |
MAS029 # 02 Y:2012 | 02 | 2012 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $12,915 | $22,500 | Not Implemented |
MAS029 # 03 Y:2012 | 03 | 2012 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,202 | $22,100 | Not Implemented |
MAS029 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,313 | $4,270 | Implemented |
MAS029 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,392 | $0 | Implemented |
MAS029 # 06 Y:2012 | 06 | 2012 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,176 | $3,920 | Not Implemented |
UA0087 # 01 Y:2012 | 01 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,153 | $960 | Not Implemented |
UA0087 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,463 | $2,000 | Implemented |
UA0087 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,286 | $1,843 | Not Implemented |
UA0087 # 04 Y:2012 | 04 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $10,082 | $1,700 | Implemented |
UA0087 # 05 Y:2012 | 05 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,599 | $3,290 | Not Implemented |
UA0087 # 06 Y:2012 | 06 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,878 | $1,875 | Not Implemented |
UA0087 # 07 Y:2012 | 07 | 2012 | INSTALL OCCUPANCY SENSORS | $2,185 | $217 | Not Implemented |
CO0664 # 01 Y:2012 | 01 | 2012 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,690 | $10,600 | Not Implemented |
CO0664 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,660 | $410 | Implemented |
CO0664 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,630 | $8,120 | Implemented |
CO0664 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $1,710 | $2,560 | Not Implemented |
MZ0097 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $230,479 | $107,601 | Not Implemented |
MZ0097 # 02 Y:2012 | 02 | 2012 | INSULATE BARE EQUIPMENT | $106,168 | $10,690 | Not Implemented |
MZ0097 # 03 Y:2012 | 03 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $60,715 | $105,000 | Not Implemented |
MZ0097 # 04 Y:2012 | 04 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $49,961 | $5,000 | Not Implemented |
MZ0097 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $29,305 | $35,000 | Implemented |