Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0452 # 11 Y:2012 | 11 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,487 | $10,561 | Not Implemented |
WV0452 # 12 Y:2012 | 12 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,146 | $618 | Implemented |
WV0452 # 13 Y:2012 | 13 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,098 | $1,105 | Implemented |
WV0452 # 14 Y:2012 | 14 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $873 | $4,350 | Not Implemented |
WV0452 # 15 Y:2012 | 15 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $431 | $1,505 | Not Implemented |
WV0452 # 16 Y:2012 | 16 | 2012 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $277 | $85 | Implemented |
NC0457 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,926 | $7,711 | Implemented |
NC0457 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $415 | $525 | Implemented |
NC0457 # 03 Y:2012 | 03 | 2012 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $19,472 | $40,000 | Not Implemented |
NC0457 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $508 | $400 | Implemented |
NC0457 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,516 | $0 | Implemented |
NC0457 # 06 Y:2012 | 06 | 2012 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,161 | $2,000 | Not Implemented |
NC0458 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $453 | $100 | Implemented |
NC0458 # 02 Y:2012 | 02 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,650 | $1,040 | Not Implemented |
NC0458 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,851 | $26,563 | Implemented |
NC0458 # 04 Y:2012 | 04 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,659 | $441 | Implemented |
NC0458 # 05 Y:2012 | 05 | 2012 | USE PHOTOCELL CONTROLS | $169 | $250 | Implemented |
NC0458 # 06 Y:2012 | 06 | 2012 | IMPROVE SPACE COMFORT CONDITIONING | $83,263 | $35,225 | Not Implemented |
NC0458 # 07 Y:2012 | 07 | 2012 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $196,000 | $25,000 | Not Implemented |
NC0458 # 08 Y:2012 | 08 | 2012 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $211,680 | $48,800 | Implemented |
SF0418 # 01 Y:2012 | 01 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $40,533 | $0 | Implemented |
SF0418 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,408 | $0 | Implemented |
SF0418 # 03 Y:2012 | 03 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $10,193 | $9,787 | Not Implemented |
SF0418 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,230 | $15,467 | Implemented |
SF0418 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $1,301 | $8,388 | Implemented |