Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0626 # 04 Y:2007 | 04 | 2007 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $3,465 | $2,500 | Not Implemented |
MA0626 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,602 | $5,481 | Not Implemented |
MA0626 # 06 Y:2007 | 06 | 2007 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $395 | $200 | Not Implemented |
WV0366 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,251 | $20,735 | Implemented |
WV0366 # 02 Y:2007 | 02 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,342 | $0 | Implemented |
WV0366 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,515 | $540 | Not Implemented |
WV0366 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,238 | $5,148 | Implemented |
WV0366 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,696 | $1,315 | Implemented |
WV0366 # 06 Y:2007 | 06 | 2007 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $5,275 | $7,600 | Not Implemented |
WV0366 # 07 Y:2007 | 07 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,217 | $1,000 | Not Implemented |
WV0366 # 08 Y:2007 | 08 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,400 | $1,050 | Implemented |
WV0366 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,252 | $0 | Implemented |
WV0366 # 10 Y:2007 | 10 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $2,440 | $898 | Implemented |
WV0366 # 11 Y:2007 | 11 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,157 | $1,030 | Not Implemented |
WV0366 # 12 Y:2007 | 12 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,770 | $5,600 | Not Implemented |
WV0366 # 13 Y:2007 | 13 | 2007 | OPTIMIZE PLANT POWER FACTOR | $1,723 | $5,600 | Not Implemented |
WV0366 # 14 Y:2007 | 14 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,641 | $165 | Not Implemented |
WV0366 # 15 Y:2007 | 15 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $751 | $1,641 | Not Implemented |
WV0366 # 16 Y:2007 | 16 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $667 | $282 | Implemented |
OR0524 # 01 Y:2007 | 01 | 2007 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $489,500 | $250,000 | Implemented |
OR0524 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,300 | $3,500 | Implemented |
OR0524 # 03 Y:2007 | 03 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $13,700 | $35,000 | Implemented |
OR0524 # 04 Y:2007 | 04 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,100 | $0 | Implemented |
OR0524 # 05 Y:2007 | 05 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,000 | $0 | Not Implemented |
OR0524 # 06 Y:2007 | 06 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,800 | $1,300 | Not Implemented |