Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
199
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0279 # 02 Y:2022 | 02 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $12,173 | $63,875 | Not Implemented |
TT0279 # 01 Y:2022 | 01 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $43,670 | $43,750 | Implemented |
TT0279 # 03 Y:2022 | 03 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,514 | $12,000 | Not Implemented |
TT0279 # 05 Y:2022 | 05 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,432 | $4,000 | Not Implemented |
TT0275 # 04 Y:2022 | 04 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $8,032 | $30,830 | Not Implemented |
TT0275 # 06 Y:2022 | 06 | 2022 | AIR CONDITION ONLY SPACE NECESSARY | $3,488 | $9,000 | Implemented |
TT0275 # 08 Y:2022 | 08 | 2022 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,083 | $500 | Not Implemented |
TT0275 # 07 Y:2022 | 07 | 2022 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,643 | $2,500 | Not Implemented |
TT0275 # 05 Y:2022 | 05 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,126 | $50 | Not Implemented |
TT0275 # 02 Y:2022 | 02 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,633 | $2,905 | Implemented |
TT0275 # 03 Y:2022 | 03 | 2022 | IMPROVE SPACE COMFORT CONDITIONING | $11,751 | $28,120 | Not Implemented |
TT0275 # 01 Y:2022 | 01 | 2022 | OPTIMIZE PLANT POWER FACTOR | $32,630 | $34,500 | Not Implemented |
TT0250 # 02 Y:2021 | 02 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,326 | $27,000 | Implemented |
TT0250 # 03 Y:2021 | 03 | 2021 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,205 | $3,000 | Not Implemented |
TT0250 # 05 Y:2021 | 05 | 2021 | INSTALL TIMERS AND/OR THERMOSTATS | $1,600 | $160 | Not Implemented |
TT0250 # 04 Y:2021 | 04 | 2021 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $2,240 | $4,500 | Implemented |
TT0250 # 01 Y:2021 | 01 | 2021 | INCREASE EFFICIENCY OF TRUCKS | $17,586 | $0 | Implemented |
TT0250 # 06 Y:2021 | 06 | 2021 | UPGRADE CONTROLS ON COMPRESSORS | $1,587 | $3,500 | Implemented |
TT0250 # 08 Y:2021 | 08 | 2021 | INSTALL OCCUPANCY SENSORS | $1,245 | $1,068 | Not Implemented |
TT0250 # 07 Y:2021 | 07 | 2021 | AVOID EMERGENCY REWIND OF MOTORS | $1,333 | $400 | Implemented |
TT0245 # 04 Y:2020 | 04 | 2020 | INSTALL TIMERS AND/OR THERMOSTATS | $1,356 | $900 | Not Implemented |
TT0245 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,143 | $150 | Implemented |
TT0245 # 03 Y:2020 | 03 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,789 | $4,500 | Not Implemented |
TT0245 # 01 Y:2020 | 01 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,084 | $1,500 | Implemented |
TT0220 # 07 Y:2019 | 07 | 2019 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,624 | $2,150 | Not Implemented |