Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0733 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,688 | $59,616 | Implemented |
UD0733 # 04 Y:2006 | 04 | 2006 | RECOVER AND REUSE WASTE MATERIAL | $8,505 | $5,000 | Implemented |
UD0733 # 05 Y:2006 | 05 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $5,125 | $0 | Implemented |
UD0733 # 06 Y:2006 | 06 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,136 | $0 | Not Implemented |
UD0733 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,883 | $0 | Not Implemented |
UD0733 # 08 Y:2006 | 08 | 2006 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,035 | $0 | Not Implemented |
UD0733 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,735 | $0 | Implemented |
UD0733 # 10 Y:2006 | 10 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,267 | $0 | Not Implemented |
UD0733 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $512 | $2,200 | Implemented |
OK0720 # 01 Y:2006 | 01 | 2006 | USE OPTIMUM TEMPERATURE | $10,475 | $1,000 | Implemented |
OK0720 # 02 Y:2006 | 02 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,780 | $4,636 | Implemented |
OK0720 # 03 Y:2006 | 03 | 2006 | INCREASE USE OF AUTOMATION | $10,975 | $6,000 | Not Implemented |
OK0720 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $786 | $5,290 | Implemented |
OK0720 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,282 | $9,940 | Implemented |
OK0720 # 06 Y:2006 | 06 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,200 | $0 | Implemented |
OR0498 # 01 Y:2006 | 01 | 2006 | COVER OPEN TANKS | $7,300 | $3,600 | Implemented |
OR0498 # 02 Y:2006 | 02 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,300 | $0 | Not Implemented |
OR0498 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,300 | $2,300 | Implemented |
OR0498 # 04 Y:2006 | 04 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $1,450 | $1,800 | Not Implemented |
OR0498 # 05 Y:2006 | 05 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $600 | $400 | Implemented |
OR0498 # 06 Y:2006 | 06 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,400 | $20,000 | Implemented |
OR0498 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,600 | $17,400 | Implemented |
LL0240 # 01 Y:2006 | 01 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $40,093 | $2,862 | Implemented |
LL0240 # 02 Y:2006 | 02 | 2006 | USE PHOTOCELL CONTROLS | $28,394 | $1,110 | Implemented |
LL0240 # 03 Y:2006 | 03 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $24,138 | $143,240 | Implemented |