Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0399 # 03 Y:2005 | 03 | 2005 | USE SOLAR HEAT TO HEAT WATER | $690 | $1,100 | Not Implemented |
AS0399 # 04 Y:2005 | 04 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $318 | $506 | Not Implemented |
TA0092 # 01 Y:2005 | 01 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,280 | $2,300 | Not Implemented |
TA0092 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,280 | $1,300 | Implemented |
TA0092 # 03 Y:2005 | 03 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $3,580 | $5 | Implemented |
TA0092 # 04 Y:2005 | 04 | 2005 | REDUCE OR ELIMINATE WASTE | $2,710 | $36 | Implemented |
TA0092 # 05 Y:2005 | 05 | 2005 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $2,200 | $111 | Not Implemented |
TA0092 # 06 Y:2005 | 06 | 2005 | SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON | $1,140 | $0 | Implemented |
TA0092 # 07 Y:2005 | 07 | 2005 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $535 | $155 | Not Implemented |
TA0092 # 08 Y:2005 | 08 | 2005 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $250 | $0 | Not Implemented |
SD0359 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,184 | $24,750 | Not Implemented |
SD0359 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,898 | $600 | Implemented |
SD0359 # 03 Y:2005 | 03 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,830 | $0 | Not Implemented |
SD0359 # 04 Y:2005 | 04 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,400 | $0 | Implemented |
SD0359 # 05 Y:2005 | 05 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $4,599 | $1,388 | Implemented |
SD0359 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,417 | $59,829 | Implemented |
SD0359 # 07 Y:2005 | 07 | 2005 | INSTALL SKYLIGHTS | $1,046 | $800 | Not Implemented |
SD0359 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $102 | $100 | Implemented |
SD0359 # 09 Y:2005 | 09 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $8,102 | $0 | Not Implemented |
SD0359 # 10 Y:2005 | 10 | 2005 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,882 | $0 | Implemented |
BD0283 # 01 Y:2005 | 01 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $5,694 | $3,003 | Implemented |
BD0283 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,780 | $602 | Not Implemented |
BD0283 # 03 Y:2005 | 03 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,828 | $2 | Implemented |
BD0283 # 04 Y:2005 | 04 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $2,160 | $361 | Not Implemented |
BD0283 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,700 | $851 | Implemented |