Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
609
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0705 # 01 Y:2004 | 01 | 2004 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $50,000 | $50,000 | Implemented |
UD0705 # 02 Y:2004 | 02 | 2004 | DEVELOP STANDARD OPERATING PROCEDURES | $23,264 | $30,000 | Not Implemented |
UD0705 # 03 Y:2004 | 03 | 2004 | REDUCE SCRAP PRODUCTION | $12,990 | $0 | Implemented |
UD0705 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,980 | $0 | Not Implemented |
UD0705 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,816 | $10,800 | Not Implemented |
UD0705 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,683 | $0 | Implemented |
UD0705 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,195 | $304 | Not Implemented |
UD0705 # 08 Y:2004 | 08 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,260 | $1,722 | Not Implemented |
UD0705 # 09 Y:2004 | 09 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $1,214 | $0 | Implemented |
UD0705 # 10 Y:2004 | 10 | 2004 | COVER OPEN TANKS | $710 | $0 | Implemented |
UD0705 # 11 Y:2004 | 11 | 2004 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $83 | $0 | Implemented |
UD0698 # 01 Y:2004 | 01 | 2004 | REDUCE FLUID FLOW RATES | $12,697 | $0 | Implemented |
UD0698 # 02 Y:2004 | 02 | 2004 | COMBINE UTILITY METERS | $11,340 | $0 | Not Implemented |
UD0698 # 03 Y:2004 | 03 | 2004 | DISCONNECT BALLASTS | $7,937 | $1,195 | Not Implemented |
UD0698 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,898 | $1,635 | Implemented |
UD0698 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,310 | $0 | Not Implemented |
UD0698 # 06 Y:2004 | 06 | 2004 | IMPROVE LUBRICATION PRACTICES | $1,693 | $0 | Implemented |
UD0698 # 07 Y:2004 | 07 | 2004 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $739 | $845 | Implemented |
UD0698 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $478 | $2,248 | Not Implemented |
UD0698 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $84 | $270 | Implemented |
UM0248 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $18,156 | $2,400 | Not Implemented |
UM0248 # 02 Y:2004 | 02 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,467 | $2,000 | Implemented |
UM0248 # 03 Y:2004 | 03 | 2004 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $3,420 | $920 | Not Implemented |
UM0248 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,890 | $225 | Implemented |
UM0248 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,550 | $1,000 | Not Implemented |