IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,345

matching recommendations
Reset
NAICS 333 Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0070 # 08 Y:2004 08 2004 ELIMINATE SHIFT $15,698 $1,000 Implemented
LM0070 # 09 Y:2004 09 2004 MODIFY WORKLOAD $855,000 $50,000 Implemented
LM0070 # 10 Y:2004 10 2004 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $525,000 $21,000 Not Implemented
LM0070 # 11 Y:2004 11 2004 IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM $283,680 $6,000 Not Implemented
TA0070 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $43,350 $0 Implemented
TA0070 # 02 Y:2004 02 2004 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $21,150 $-21,150 Implemented
TA0070 # 03 Y:2004 03 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $7,300 $0 Implemented
TA0070 # 04 Y:2004 04 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,100 $590 Not Implemented
TA0070 # 05 Y:2004 05 2004 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $2,990 $130 Implemented
TA0070 # 06 Y:2004 06 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,650 $0 Implemented
TA0070 # 07 Y:2004 07 2004 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $2,088 $0 Not Implemented
TA0070 # 08 Y:2004 08 2004 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,020 $410 Implemented
TA0070 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,885 $50 Implemented
TA0070 # 10 Y:2004 10 2004 DISCONNECT BALLASTS $1,030 $200 Not Implemented
TA0070 # 11 Y:2004 11 2004 INSTALL OCCUPANCY SENSORS $680 $290 Implemented
MI0072 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $1,447 $800 Implemented
MI0072 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $-2,108 $550 Implemented
MI0072 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,341 $228 Implemented
MI0072 # 04 Y:2004 04 2004 REDUCE DEFECTS BY REDUCING PRODUCT TIPPING $221,675 $0 Implemented
MI0072 # 05 Y:2004 05 2004 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $16,550 $2,176 Not Implemented
LE0179 # 01 Y:2004 01 2004 REDUCE VENTILATION AIR $10,362 $942 Not Implemented
LE0179 # 02 Y:2004 02 2004 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,781 $0 Implemented
LE0179 # 03 Y:2004 03 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,423 $89 Implemented
LE0179 # 04 Y:2004 04 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,185 $0 Not Implemented
LE0179 # 05 Y:2004 05 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $960 $750 Not Implemented