Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,310
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0062 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $711 | $724 | Implemented |
LM0062 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $415 | $219 | Implemented |
LM0062 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,369 | $410 | Implemented |
LM0062 # 06 Y:2003 | 06 | 2003 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $3,170 | $1,950 | Not Implemented |
LM0062 # 07 Y:2003 | 07 | 2003 | IMPROVE COMBUSTION CONTROL CAPABILITY | $666 | $750 | Not Implemented |
LM0062 # 08 Y:2003 | 08 | 2003 | AIR CONDITION ONLY SPACE NECESSARY | $17,255 | $0 | Implemented |
LM0062 # 09 Y:2003 | 09 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $52,500 | $19,910 | Implemented |
LM0062 # 10 Y:2003 | 10 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $105,000 | $17,500 | Implemented |
LM0062 # 11 Y:2003 | 11 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $17,820 | $3,000 | Implemented |
LM0062 # 12 Y:2003 | 12 | 2003 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $505,164 | $0 | Implemented |
NC0257 # 01 Y:2003 | 01 | 2003 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $169,269 | $200,000 | Not Implemented |
NC0257 # 02 Y:2003 | 02 | 2003 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $24,665 | $10,000 | Not Implemented |
NC0257 # 03 Y:2003 | 03 | 2003 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $42,749 | $55,000 | Not Implemented |
NC0257 # 04 Y:2003 | 04 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $335,124 | $425,000 | n/a |
NC0257 # 05 Y:2003 | 05 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $8,216 | $8,241 | Implemented |
NC0257 # 06 Y:2003 | 06 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,771 | $2,118 | Implemented |
NC0257 # 07 Y:2003 | 07 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,455 | $500 | Implemented |
NC0257 # 08 Y:2003 | 08 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,407 | $840 | Implemented |
NC0257 # 09 Y:2003 | 09 | 2003 | USE PHOTOCELL CONTROLS | $1,346 | $1,540 | Implemented |
AM0441 # 01 Y:2003 | 01 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,700 | $410 | Implemented |
AM0441 # 02 Y:2003 | 02 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,585 | $0 | Not Implemented |
AM0441 # 03 Y:2003 | 03 | 2003 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,320 | $699 | Not Implemented |
AM0441 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,330 | $300 | Implemented |
AM0441 # 05 Y:2003 | 05 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,180 | $0 | Not Implemented |