Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
277
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0477 # 01 Y:2019 | 01 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $9,091 | $0 | Not Implemented |
LE0477 # 02 Y:2019 | 02 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $179 | $80 | Implemented |
LE0477 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,343 | $40,000 | Not Implemented |
LE0477 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,531 | $5,300 | Implemented |
LE0477 # 05 Y:2019 | 05 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $23,914 | $96,000 | Implemented |
WV0542 # 04 Y:2017 | 04 | 2017 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $4,841 | $16,500 | Not Implemented |
WV0542 # 13 Y:2017 | 13 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $926 | $100 | Implemented |
WV0542 # 14 Y:2017 | 14 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $881 | $2,150 | Not Implemented |
WV0542 # 15 Y:2017 | 15 | 2017 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $48 | $105 | Not Implemented |
WV0542 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,056 | $765 | Implemented |
WV0542 # 01 Y:2017 | 01 | 2017 | USE EVAPORATION TO CONCENTRATE MATERIAL | $9,150 | $45,000 | Not Implemented |
WV0542 # 02 Y:2017 | 02 | 2017 | INSTALL OCCUPANCY SENSORS | $5,206 | $5,330 | Implemented |
WV0542 # 12 Y:2017 | 12 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $955 | $2,135 | Implemented |
WV0542 # 10 Y:2017 | 10 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,131 | $883 | Implemented |
WV0542 # 05 Y:2017 | 05 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,681 | $2,700 | Implemented |
WV0542 # 06 Y:2017 | 06 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,665 | $0 | Implemented |
WV0542 # 07 Y:2017 | 07 | 2017 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $3,828 | $1,800 | Not Implemented |
WV0542 # 09 Y:2017 | 09 | 2017 | MINIMIZE WATER USAGE | $2,251 | $7,000 | Implemented |
WV0542 # 11 Y:2017 | 11 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $963 | $940 | Implemented |
WV0542 # 08 Y:2017 | 08 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,984 | $9,625 | Implemented |
WV0533 # 06 Y:2016 | 06 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $8,986 | $20,750 | Not Implemented |
WV0533 # 05 Y:2016 | 05 | 2016 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $9,595 | $1,000 | Implemented |
WV0533 # 04 Y:2016 | 04 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,228 | $2,417 | Implemented |
WV0533 # 03 Y:2016 | 03 | 2016 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $15,212 | $35,900 | Implemented |