Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
70
matching recommendationsNAICS | 3331 | Agriculture, Construction, and Mining Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0901 # 06 Y:2014 | 06 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $40,018 | $156,997 | Not Implemented |
OK0901 # 05 Y:2014 | 05 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $156 | $606 | Not Implemented |
OK0901 # 01 Y:2014 | 01 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,026 | $1,766 | Not Implemented |
OK0901 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,047 | $1,378 | Not Implemented |
OK0901 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,102 | $1,890 | Not Implemented |
OK0901 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,328 | $24,267 | Not Implemented |
OK0895 # 02 Y:2014 | 02 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $383 | $678 | Not Implemented |
OK0895 # 11 Y:2014 | 11 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $182 | $158 | Not Implemented |
OK0895 # 13 Y:2014 | 13 | 2014 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,006 | $0 | Not Implemented |
OK0895 # 10 Y:2014 | 10 | 2014 | INSULATE BARE EQUIPMENT | $9,518 | $5,258 | Not Implemented |
OK0895 # 09 Y:2014 | 09 | 2014 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $854 | $70 | Implemented |
OK0895 # 08 Y:2014 | 08 | 2014 | INSULATE BARE EQUIPMENT | $16,794 | $3,436 | Not Implemented |
OK0895 # 07 Y:2014 | 07 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,028 | $32,400 | Not Implemented |
OK0895 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,754 | $5,850 | Not Implemented |
OK0895 # 05 Y:2014 | 05 | 2014 | USE PHOTOCELL CONTROLS | $16,923 | $24,600 | Not Implemented |
OK0895 # 12 Y:2014 | 12 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,033 | $14,580 | Not Implemented |
OK0895 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $706 | $1,400 | Implemented |
OK0895 # 01 Y:2014 | 01 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $829 | $689 | Not Implemented |
OK0895 # 04 Y:2014 | 04 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $669 | $1,452 | Implemented |
WM0051 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,050 | $225 | Implemented |
WM0051 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,680 | $3,200 | Not Implemented |
WM0051 # 07 Y:2014 | 07 | 2014 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $9,345 | $35,000 | Not Implemented |
WM0051 # 09 Y:2014 | 09 | 2014 | REPLACE BOILER | $11,306 | $16,000 | Implemented |
WM0051 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,680 | $5,175 | Not Implemented |
WM0051 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $15,358 | $6,250 | Not Implemented |