Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
332
matching recommendationsNAICS | 33311 | Agricultural Implement Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0360 # 07 Y:2005 | 07 | 2005 | MAINTAIN MACHINES TO REDUCE LEAKS | $656 | $147 | Implemented |
IA0360 # 08 Y:2005 | 08 | 2005 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $2,470 | $400 | Not Implemented |
IA0360 # 09 Y:2005 | 09 | 2005 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $3,570 | $400 | Implemented |
SU0203 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,139 | $0 | Not Implemented |
SU0203 # 02 Y:2005 | 02 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,582 | $0 | Not Implemented |
SU0203 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,367 | $366 | Implemented |
SU0203 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,129 | $308 | Implemented |
SU0203 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,105 | $960 | Implemented |
SU0203 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $1,344 | $1,090 | Not Implemented |
SU0203 # 07 Y:2005 | 07 | 2005 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $16,477 | $25,850 | Not Implemented |
AS0384 # 01 Y:2004 | 01 | 2004 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $58,500 | $1,130 | Not Implemented |
AS0384 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $34,877 | $495 | Not Implemented |
AS0384 # 03 Y:2004 | 03 | 2004 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $26,000 | $22,316 | Implemented |
AS0384 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,206 | $88,805 | Not Implemented |
AS0384 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,859 | $180 | Implemented |
AS0384 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,696 | $3,600 | Not Implemented |
AS0384 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,575 | $20 | Implemented |
AS0384 # 08 Y:2004 | 08 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $904 | $961 | Not Implemented |
AS0384 # 09 Y:2004 | 09 | 2004 | INSULATE BARE EQUIPMENT | $902 | $251 | Implemented |
IA0341 # 01 Y:2004 | 01 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $7,506 | $1,200 | Not Implemented |
IA0341 # 02 Y:2004 | 02 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $2,502 | $700 | Implemented |
IA0341 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,519 | $460 | Implemented |
IA0341 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $727 | $105 | Implemented |
IA0341 # 05 Y:2004 | 05 | 2004 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $8,040 | $54,300 | Implemented |
IA0341 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $182 | $194 | Implemented |