IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

316

matching recommendations
Reset
NAICS 33312 Construction Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0108 # 05 Y:2006 05 2006 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS $9,940 $30,000 Not Implemented
BD0301 # 01 Y:2006 01 2006 USE RADIANT HEATER FOR SPOT HEATING $94,570 $91,000 Implemented
BD0301 # 02 Y:2006 02 2006 RECOVER WASTE HEAT FROM EQUIPMENT $43,599 $22,780 Implemented
BD0301 # 03 Y:2006 03 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,786 $1,800 Implemented
BD0301 # 04 Y:2006 04 2006 USE PHOTOCELL CONTROLS $1,759 $1,750 Implemented
BD0301 # 05 Y:2006 05 2006 RECOVER WASTE HEAT FROM EQUIPMENT $1,640 $500 Implemented
BD0301 # 06 Y:2006 06 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $911 $1,960 Not Implemented
BD0301 # 07 Y:2006 07 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $763 $500 Implemented
BD0301 # 08 Y:2006 08 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $342 $350 Implemented
BD0301 # 09 Y:2006 09 2006 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $40,050 $22,800 Not Implemented
BD0301 # 10 Y:2006 10 2006 $1,669,200 $285,000 Implemented
BD0301 # 11 Y:2006 11 2006 $995 $0 Implemented
CO0577 # 01 Y:2005 01 2005 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $141,620 $513,000 Not Implemented
CO0577 # 02 Y:2005 02 2005 OPTIMIZE PLANT POWER FACTOR $135,890 $303,800 Implemented
CO0577 # 03 Y:2005 03 2005 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $89,400 $41,000 Implemented
CO0577 # 04 Y:2005 04 2005 $48,020 $360 Implemented
CO0577 # 05 Y:2005 05 2005 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $3,420 $6,000 Implemented
CO0577 # 06 Y:2005 06 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $270 $340 Implemented
CO0577 # 07 Y:2005 07 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $810 $3,070 Not Implemented
CO0577 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $38,530 $150,890 Not Implemented
UD0698 # 01 Y:2004 01 2004 REDUCE FLUID FLOW RATES $12,697 $0 Implemented
UD0698 # 02 Y:2004 02 2004 COMBINE UTILITY METERS $11,340 $0 Not Implemented
UD0698 # 03 Y:2004 03 2004 DISCONNECT BALLASTS $7,937 $1,195 Not Implemented
UD0698 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,898 $1,635 Implemented
UD0698 # 05 Y:2004 05 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,310 $0 Not Implemented