Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
81
matching recommendationsNAICS | 333131 | Mining Machinery and Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0455 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $6,580 | $2,250 | Implemented |
BD0455 # 09 Y:2015 | 09 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,388 | $25 | Implemented |
BD0455 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $839 | $725 | Implemented |
OR0608 # 02 Y:2013 | 02 | 2013 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $107,138 | $55,641 | Implemented |
OR0608 # 01 Y:2013 | 01 | 2013 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $32,340 | $0 | Implemented |
WV0379 # 04 Y:2008 | 04 | 2008 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $10,617 | $13,800 | Implemented |
WV0379 # 15 Y:2008 | 15 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $700 | $1,125 | Implemented |
WV0379 # 14 Y:2008 | 14 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,500 | $2,050 | Implemented |
WV0379 # 13 Y:2008 | 13 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,578 | $4,167 | Implemented |
WV0379 # 12 Y:2008 | 12 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,133 | $160 | Implemented |
WV0379 # 11 Y:2008 | 11 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $2,610 | $763 | Implemented |
WV0379 # 10 Y:2008 | 10 | 2008 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,723 | $1,000 | Implemented |
WV0379 # 09 Y:2008 | 09 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,760 | $0 | Implemented |
WV0379 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,550 | $0 | Implemented |
WV0379 # 06 Y:2008 | 06 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,977 | $700 | Implemented |
WV0379 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,262 | $1,080 | Implemented |
WV0379 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,378 | $60,703 | Implemented |
WV0379 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $72,979 | $113,775 | Implemented |
MZ0008 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,856 | $21,050 | Implemented |
MZ0008 # 02 Y:2007 | 02 | 2007 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $44,772 | $6,399 | Implemented |
MZ0008 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,289 | $800 | Implemented |
MZ0008 # 04 Y:2007 | 04 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $694 | $1,300 | Implemented |
MZ0008 # 05 Y:2007 | 05 | 2007 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $812 | $0 | Implemented |
MZ0008 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22 | $23 | Implemented |
TA0129 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,250 | $1,944 | Implemented |