Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

70

matching recommendations
Reset
NAICS 333243 Sawmill, Woodworking, and Paper Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0122 # 03 Y:2014 03 2014 COMBINE UTILITY METERS $87 $0 Not Implemented
UA0122 # 02 Y:2014 02 2014 MODIFY STARTUP/SHUTDOWN TIMES $13,749 $0 Not Implemented
DL0085 # 02 Y:2012 02 2012 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,948 $100 Implemented
DL0085 # 12 Y:2012 12 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $1,010 $500 Not Implemented
DL0085 # 01 Y:2012 01 2012 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $37,175 $100 Not Implemented
DL0085 # 03 Y:2012 03 2012 RECOVER WASTE HEAT FROM EQUIPMENT $9,212 $6,080 Implemented
DL0085 # 04 Y:2012 04 2012 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $25,500 $21,080 Implemented
DL0085 # 05 Y:2012 05 2012 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $32,910 $51,500 Implemented
DL0085 # 06 Y:2012 06 2012 RECOVER WASTE HEAT FROM EQUIPMENT $7,995 $4,850 Implemented
DL0085 # 07 Y:2012 07 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,020 $2,800 Implemented
DL0085 # 08 Y:2012 08 2012 INSTALL OCCUPANCY SENSORS $2,640 $620 Implemented
DL0085 # 09 Y:2012 09 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $23,794 $80,000 Not Implemented
DL0085 # 10 Y:2012 10 2012 REVISE SMOKE CLEANUP FROM OPERATIONS $3,290 $11,200 Implemented
DL0085 # 11 Y:2012 11 2012 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $5,894 $11,040 Not Implemented
NC0379 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $101 $308 Implemented
NC0379 # 08 Y:2008 08 2008 DEVELOP A REPAIR/REPLACE POLICY $834 $1,728 Implemented
NC0379 # 01 Y:2008 01 2008 ADJUST BURNERS FOR EFFICIENT OPERATION $871 $800 Implemented
NC0379 # 02 Y:2008 02 2008 LOWER OPERATING PRESSURE OF CONDENSER (STEAM) $333 $100 Implemented
NC0379 # 03 Y:2008 03 2008 REDUCE VENTILATION AIR $7,706 $25,500 Not Implemented
NC0379 # 04 Y:2008 04 2008 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $2,284 $3,000 Implemented
NC0379 # 05 Y:2008 05 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $237 $50 Implemented
NC0379 # 06 Y:2008 06 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $269 $100 Implemented
OR0524 # 01 Y:2007 01 2007 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $489,500 $250,000 Implemented
OR0524 # 05 Y:2007 05 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,000 $0 Not Implemented
OR0524 # 06 Y:2007 06 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,800 $1,300 Not Implemented