Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
483
matching recommendationsNAICS | 3333 | Commercial and Service Industry Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0237 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,086 | $80 | Implemented |
MI0237 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,565 | $1,660 | Implemented |
MI0237 # 06 Y:2013 | 06 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,104 | $2,406 | Implemented |
MI0237 # 07 Y:2013 | 07 | 2013 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $1,045 | $40 | Implemented |
MI0237 # 08 Y:2013 | 08 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $714 | $205 | Implemented |
MI0237 # 09 Y:2013 | 09 | 2013 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $639 | $1,240 | Not Implemented |
MI0237 # 10 Y:2013 | 10 | 2013 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $396 | $1,880 | Implemented |
MA0704 # 01 Y:2013 | 01 | 2013 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $10,351 | $200 | Not Implemented |
MA0704 # 02 Y:2013 | 02 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,747 | $9,100 | Not Implemented |
MA0704 # 03 Y:2013 | 03 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,329 | $5,680 | Not Implemented |
MA0704 # 04 Y:2013 | 04 | 2013 | REDUCE VENTILATION AIR | $2,055 | $5,900 | Implemented |
MA0704 # 05 Y:2013 | 05 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,765 | $500 | Not Implemented |
MA0704 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $601 | $2,200 | Not Implemented |
SD0460 # 01 Y:2013 | 01 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $50,132 | $152,300 | Implemented |
SD0460 # 02 Y:2013 | 02 | 2013 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $48,502 | $119,500 | Not Implemented |
SD0460 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,357 | $1,000 | Implemented |
SD0460 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,875 | $900 | Implemented |
SD0460 # 05 Y:2013 | 05 | 2013 | REPLACE BOILER | $4,735 | $14,250 | Not Implemented |
SD0460 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,847 | $7,050 | Not Implemented |
SD0460 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,515 | $3,212 | Implemented |
SD0460 # 08 Y:2013 | 08 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,570 | $200 | Implemented |
SD0460 # 09 Y:2013 | 09 | 2013 | USE PHOTOCELL CONTROLS | $1,249 | $1,100 | Not Implemented |
SD0460 # 10 Y:2013 | 10 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $731 | $2,500 | Implemented |
SU0327 # 01 Y:2012 | 01 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $728 | $0 | Implemented |
SU0327 # 02 Y:2012 | 02 | 2012 | PAY BILLS ON TIME TO AVOID LATE FEES | $287 | $0 | Not Implemented |