Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
958
matching recommendationsNAICS | 3334 | Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0393 # 04 Y:2005 | 04 | 2005 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $2,674 | $5,500 | Not Implemented |
AS0393 # 05 Y:2005 | 05 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,250 | $12,278 | Implemented |
AS0393 # 06 Y:2005 | 06 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,527 | $70 | Implemented |
AS0393 # 07 Y:2005 | 07 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,152 | $1,260 | Implemented |
AS0393 # 08 Y:2005 | 08 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $968 | $3,000 | Implemented |
AS0393 # 09 Y:2005 | 09 | 2005 | INSTALL OCCUPANCY SENSORS | $324 | $350 | Not Implemented |
AS0393 # 10 Y:2005 | 10 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $108 | $224 | Implemented |
GT0789 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $63,136 | $0 | Implemented |
GT0789 # 02 Y:2004 | 02 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $3,090 | $1,824 | Implemented |
GT0789 # 03 Y:2004 | 03 | 2004 | DISCONNECT BALLASTS | $639 | $645 | Implemented |
GT0789 # 04 Y:2004 | 04 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $5,717 | $300 | Not Implemented |
GT0789 # 05 Y:2004 | 05 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $21,400 | $9,700 | Implemented |
GT0789 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,160 | $2,400 | Implemented |
GT0789 # 07 Y:2004 | 07 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,570 | $6,000 | Implemented |
GT0789 # 08 Y:2004 | 08 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $964 | $2,900 | Not Implemented |
GT0789 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $55,800 | $198,000 | Implemented |
OK0692 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,239 | $2,275 | Implemented |
OK0692 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,206 | $10,250 | Not Implemented |
OK0692 # 03 Y:2004 | 03 | 2004 | USE COMPRESSOR AIR FILTERS | $5,114 | $7,875 | Not Implemented |
OK0692 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,221 | $8,625 | Implemented |
OK0692 # 05 Y:2004 | 05 | 2004 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,389 | $6,675 | Not Implemented |
OK0692 # 06 Y:2004 | 06 | 2004 | INSTALL SET-BACK TIMERS | $81,447 | $10,000 | Implemented |
OK0692 # 07 Y:2004 | 07 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $8,800 | $0 | Implemented |
OK0692 # 08 Y:2004 | 08 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $17,464 | $5,050 | Not Implemented |
OK0692 # 09 Y:2004 | 09 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $663,000 | $130,000 | Not Implemented |