IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

130

matching recommendations
Reset
NAICS 333611 Turbine and Turbine Generator Set Units Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0387 # 04 Y:2006 04 2006 AIR CONDITION ONLY SPACE NECESSARY $2,639 $3,360 Not Implemented
UF0387 # 05 Y:2006 05 2006 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $4,265 $578 Not Implemented
UF0387 # 06 Y:2006 06 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,577 $370 Implemented
UF0387 # 07 Y:2006 07 2006 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $21,479 $0 Implemented
UF0387 # 08 Y:2006 08 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,017 $0 Implemented
UF0387 # 09 Y:2006 09 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,106 $6,458 Implemented
UF0387 # 10 Y:2006 10 2006 INSTALL OCCUPANCY SENSORS $209 $140 Not Implemented
UU0072 # 01 Y:2004 01 2004 OPTIMIZE PLANT POWER FACTOR $17,050 $21,660 Not Implemented
UU0072 # 02 Y:2004 02 2004 USE DEMAND CONTROLLER OR LOAD SHEDDER $10,670 $10,000 Not Implemented
UU0072 # 03 Y:2004 03 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $16,150 $17,500 Not Implemented
UU0072 # 04 Y:2004 04 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,450 $8,500 Not Implemented
UU0072 # 05 Y:2004 05 2004 INSTALL OCCUPANCY SENSORS $940 $600 Not Implemented
UU0072 # 06 Y:2004 06 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $203,380 $800,000 Not Implemented
UU0072 # 07 Y:2004 07 2004 REPROCESS SPENT OILS ON SITE FOR RE-USE $34,700 $6,000 Not Implemented
LL0174 # 01 Y:2003 01 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $17,499 $7,098 Not Implemented
LL0174 # 02 Y:2003 02 2003 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,785 $880 Implemented
LL0174 # 03 Y:2003 03 2003 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,515 $763 Not Implemented
LL0174 # 04 Y:2003 04 2003 USE PHOTOCELL CONTROLS $582 $28 Implemented
LL0174 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $443 $360 Not Implemented
LL0174 # 06 Y:2003 06 2003 INSTALL OCCUPANCY SENSORS $384 $56 Implemented
LL0174 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $386 $280 Implemented
LL0174 # 08 Y:2003 08 2003 $430 $32 Not Implemented
NC0263 # 01 Y:2003 01 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $118,487 $500 Not Implemented
NC0263 # 02 Y:2003 02 2003 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT $22,423 $10,000 Not Implemented
NC0263 # 03 Y:2003 03 2003 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $33,114 $24,600 Not Implemented