Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
43
matching recommendationsNAICS | 333612 | Speed Changer, Industrial High-Speed Drive, and Gear Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UC2201 # 09 Y:2022 | 09 | 2022 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,563 | $0 | Implemented |
UC2201 # 04 Y:2022 | 04 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,728 | $2,000 | Implemented |
UC2201 # 01 Y:2022 | 01 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,041 | $56,085 | Implemented |
UC2201 # 03 Y:2022 | 03 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,036 | $48,285 | Implemented |
UC2201 # 08 Y:2022 | 08 | 2022 | PAY UTILITY BILLS ON TIME | $530 | $0 | Implemented |
SU0485 # 02 Y:2019 | 02 | 2019 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,064 | $264 | Implemented |
SU0485 # 07 Y:2019 | 07 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,923 | $2,832 | Implemented |
SU0485 # 08 Y:2019 | 08 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $387 | $415 | Implemented |
SU0485 # 10 Y:2019 | 10 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,242 | $26,026 | Implemented |
SU0485 # 09 Y:2019 | 09 | 2019 | USE PHOTOCELL CONTROLS | $1,305 | $1,645 | Implemented |
NC0560 # 03 Y:2016 | 03 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,460 | $200 | Implemented |
NC0560 # 14 Y:2016 | 14 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,514 | $5,865 | Implemented |
NC0560 # 04 Y:2016 | 04 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $17,627 | $1,000 | Implemented |
NC0560 # 05 Y:2016 | 05 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,243 | $26,000 | Implemented |
NC0560 # 10 Y:2016 | 10 | 2016 | INSTALL OCCUPANCY SENSORS | $519 | $521 | Implemented |
NC0560 # 11 Y:2016 | 11 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $474 | $455 | Implemented |
NC0560 # 12 Y:2016 | 12 | 2016 | USE PHOTOCELL CONTROLS | $194 | $250 | Implemented |
NC0560 # 13 Y:2016 | 13 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,597 | $500 | Implemented |
NC0560 # 02 Y:2016 | 02 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,200 | $4,000 | Implemented |
DL0094 # 04 Y:2012 | 04 | 2012 | AIR CONDITION ONLY SPACE NECESSARY | $780 | $0 | Implemented |
DL0094 # 01 Y:2012 | 01 | 2012 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,550 | $0 | Implemented |
OK0816 # 10 Y:2011 | 10 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,037 | $0 | Implemented |
OK0816 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $245 | $1,488 | Implemented |
OK0816 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $391 | $456 | Implemented |
OK0816 # 08 Y:2011 | 08 | 2011 | REPLACE BOILER | $26,135 | $24,220 | Implemented |