Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsNAICS | 3339 | Other General Purpose Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0897 # 01 Y:2014 | 01 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,056 | $0 | Implemented |
OK0897 # 07 Y:2014 | 07 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,545 | $3,641 | Implemented |
OK0897 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,792 | $1,656 | Implemented |
OK0897 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,000 | $10,067 | Implemented |
OK0897 # 04 Y:2014 | 04 | 2014 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $248 | $0 | Implemented |
OK0897 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,796 | $2,066 | Implemented |
OK0897 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,440 | $1,188 | Implemented |
TT0070 # 02 Y:2011 | 02 | 2011 | INSULATE BARE EQUIPMENT | $7,025 | $2,100 | Not Implemented |
TT0070 # 09 Y:2011 | 09 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $5,985 | $1,347 | Not Implemented |
TT0070 # 08 Y:2011 | 08 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $11,486 | $102,000 | Not Implemented |
TT0070 # 07 Y:2011 | 07 | 2011 | OPTIMIZE PLANT POWER FACTOR | $6,582 | $32,600 | Not Implemented |
TT0070 # 06 Y:2011 | 06 | 2011 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $1,730 | $4,900 | Not Implemented |
TT0070 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,337 | $21,600 | Not Implemented |
TT0070 # 04 Y:2011 | 04 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $875 | $1,200 | Not Implemented |
TT0070 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $1,990 | $1,600 | Not Implemented |
TT0070 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,235 | $0 | Not Implemented |
OK0805 # 02 Y:2011 | 02 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $21,982 | $8,893 | Not Implemented |
OK0805 # 01 Y:2011 | 01 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $165,120 | $3,385 | Implemented |
OK0805 # 03 Y:2011 | 03 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $98,548 | $15,600 | Implemented |
OK0805 # 04 Y:2011 | 04 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $17,316 | $4,650 | Not Implemented |
LL0168 # 06 Y:2003 | 06 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $981 | $20 | Not Implemented |
LL0168 # 05 Y:2003 | 05 | 2003 | USE PHOTOCELL CONTROLS | $1,257 | $1,784 | Not Implemented |
LL0168 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,845 | $4,800 | Implemented |
LL0168 # 02 Y:2003 | 02 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,916 | $900 | Not Implemented |
LL0168 # 01 Y:2003 | 01 | 2003 | USE PHOTOCELL CONTROLS | $8,239 | $1,196 | Not Implemented |