Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,619
matching recommendationsNAICS | 3339 | Other General Purpose Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0542 # 01 Y:2017 | 01 | 2017 | USE EVAPORATION TO CONCENTRATE MATERIAL | $9,150 | $45,000 | Not Implemented |
WV0542 # 02 Y:2017 | 02 | 2017 | INSTALL OCCUPANCY SENSORS | $5,206 | $5,330 | Implemented |
WV0542 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,056 | $765 | Implemented |
WV0542 # 04 Y:2017 | 04 | 2017 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $4,841 | $16,500 | Not Implemented |
WV0542 # 05 Y:2017 | 05 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,681 | $2,700 | Implemented |
WV0542 # 06 Y:2017 | 06 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,665 | $0 | Implemented |
WV0542 # 07 Y:2017 | 07 | 2017 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $3,828 | $1,800 | Not Implemented |
WV0542 # 08 Y:2017 | 08 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,984 | $9,625 | Implemented |
WV0542 # 09 Y:2017 | 09 | 2017 | MINIMIZE WATER USAGE | $2,251 | $7,000 | Implemented |
WV0542 # 10 Y:2017 | 10 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,131 | $883 | Implemented |
WV0542 # 11 Y:2017 | 11 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $963 | $940 | Implemented |
WV0542 # 12 Y:2017 | 12 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $955 | $2,135 | Implemented |
WV0542 # 13 Y:2017 | 13 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $926 | $100 | Implemented |
WV0542 # 14 Y:2017 | 14 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $881 | $2,150 | Not Implemented |
WV0542 # 15 Y:2017 | 15 | 2017 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $48 | $105 | Not Implemented |
SF0499 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,800 | $0 | Implemented |
SF0499 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,955 | $0 | Implemented |
SF0499 # 03 Y:2017 | 03 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $600 | $0 | Not Implemented |
SF0499 # 04 Y:2017 | 04 | 2017 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $18,778 | $30,000 | Implemented |
SF0499 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,191 | $12,954 | Implemented |
SF0499 # 06 Y:2017 | 06 | 2017 | USE SOLAR HEAT TO MAKE ELECTRICTY | $77,403 | $434,700 | Implemented |
NC0587 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $64,592 | $221,073 | Implemented |
NC0587 # 02 Y:2017 | 02 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $375 | $75 | Not Implemented |
NC0587 # 03 Y:2017 | 03 | 2017 | INSTALL OCCUPANCY SENSORS | $798 | $400 | Implemented |
NC0587 # 04 Y:2017 | 04 | 2017 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $62,705 | $158,000 | Not Implemented |