Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,619
matching recommendationsNAICS | 3339 | Other General Purpose Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0075 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,771 | $1,152 | Implemented |
TT0075 # 08 Y:2011 | 08 | 2011 | ISOLATE HOT OR COLD EQUIPMENT | $1,379 | $2,500 | Implemented |
TT0075 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,369 | $5,436 | Not Implemented |
OK0815 # 01 Y:2011 | 01 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $57,281 | $13,000 | Not Implemented |
OK0815 # 02 Y:2011 | 02 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $12,351 | $0 | Implemented |
OK0815 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,341 | $930 | Implemented |
OK0815 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $340 | $950 | Implemented |
OK0815 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $2,608 | $2,198 | Not Implemented |
OK0815 # 06 Y:2011 | 06 | 2011 | DISCONNECT BALLASTS | $849 | $696 | Not Implemented |
OK0815 # 07 Y:2011 | 07 | 2011 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $15,876 | $3,096 | Not Implemented |
OK0815 # 08 Y:2011 | 08 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,335 | $20,544 | Not Implemented |
OK0815 # 09 Y:2011 | 09 | 2011 | INSULATE BARE EQUIPMENT | $3,531 | $633 | Implemented |
UA0065 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,459 | $24,444 | Not Implemented |
UA0065 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $668 | $1,241 | Implemented |
UA0065 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,025 | $800 | Not Implemented |
UA0065 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $702 | $1,100 | Implemented |
UA0065 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $832 | $1,935 | Not Implemented |
UA0065 # 06 Y:2011 | 06 | 2011 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $510 | $1,533 | Not Implemented |
IA0465 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,456 | $246 | Not Implemented |
IA0465 # 02 Y:2011 | 02 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,745 | $396 | Not Implemented |
IA0465 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,614 | $7,406 | Not Implemented |
IA0465 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,910 | $60,314 | Not Implemented |
IA0465 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $1,368 | $616 | Not Implemented |
IA0465 # 06 Y:2011 | 06 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $302 | $13 | Not Implemented |
IA0465 # 07 Y:2011 | 07 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,240 | $8,646 | Not Implemented |