Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
164
matching recommendationsNAICS | 3339 | Other General Purpose Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0456 # 09 Y:2012 | 09 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,207 | $5,050 | Not Implemented |
WV0456 # 10 Y:2012 | 10 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,040 | $2,069 | Implemented |
WV0456 # 11 Y:2012 | 11 | 2012 | IMPROVE LUBRICATION PRACTICES | $1,660 | $1,000 | Implemented |
WV0456 # 12 Y:2012 | 12 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,637 | $2,475 | Implemented |
WV0456 # 13 Y:2012 | 13 | 2012 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,180 | $1,000 | Implemented |
WV0456 # 14 Y:2012 | 14 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,129 | $555 | Implemented |
WV0456 # 15 Y:2012 | 15 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,089 | $981 | Implemented |
WV0456 # 16 Y:2012 | 16 | 2012 | USE PHOTOCELL CONTROLS | $824 | $705 | Implemented |
UD0793 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,450 | $25,000 | Implemented |
UD0793 # 02 Y:2009 | 02 | 2009 | INSULATE BARE EQUIPMENT | $6,677 | $1,000 | Implemented |
UD0793 # 03 Y:2009 | 03 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,960 | $500 | Not Implemented |
UD0793 # 04 Y:2009 | 04 | 2009 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $3,855 | $0 | Implemented |
UD0793 # 05 Y:2009 | 05 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,799 | $400 | Not Implemented |
UD0793 # 06 Y:2009 | 06 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,114 | $0 | Implemented |
UD0793 # 07 Y:2009 | 07 | 2009 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,970 | $1,000 | Implemented |
UD0793 # 08 Y:2009 | 08 | 2009 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $2,460 | $2,500 | Implemented |
UD0793 # 09 Y:2009 | 09 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,488 | $0 | Implemented |
UD0793 # 10 Y:2009 | 10 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,256 | $4,820 | Not Implemented |
UD0793 # 11 Y:2009 | 11 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $621 | $1,000 | Implemented |
UD0793 # 12 Y:2009 | 12 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $435 | $0 | Not Implemented |
UD0758 # 01 Y:2007 | 01 | 2007 | REDUCE VENTILATION AIR | $24,896 | $0 | Implemented |
UD0758 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,028 | $36,900 | Not Implemented |
UD0758 # 03 Y:2007 | 03 | 2007 | USE POWER DURING OFF-PEAK PERIODS | $12,438 | $0 | Not Implemented |
UD0758 # 04 Y:2007 | 04 | 2007 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $10,225 | $15,000 | Not Implemented |
UD0758 # 05 Y:2007 | 05 | 2007 | USE MINIMUM SAFE OVEN VENTILATION | $9,717 | $595 | Not Implemented |