Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
84
matching recommendationsNAICS | 33391 | Pump and Compressor Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0859 # 07 Y:2013 | 07 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,135 | $3,356 | Not Implemented |
OK0859 # 08 Y:2013 | 08 | 2013 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $20,774 | $7,707 | Not Implemented |
OK0859 # 09 Y:2013 | 09 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,338 | $4,600 | Not Implemented |
MZ0115 # 07 Y:2013 | 07 | 2013 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $8,261 | $750 | Not Implemented |
OK0859 # 11 Y:2013 | 11 | 2013 | INSTALL SET-BACK TIMERS | $1,753 | $460 | Not Implemented |
OK0859 # 12 Y:2013 | 12 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,487 | $3,063 | Not Implemented |
OK0859 # 13 Y:2013 | 13 | 2013 | REDUCE HEAT GAIN BY WINDOW TINTING | $3,200 | $6,500 | Implemented |
OK0859 # 14 Y:2013 | 14 | 2013 | REDUCE HEAT GAIN BY WINDOW TINTING | $372 | $0 | Implemented |
MZ0115 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,884 | $3,658 | Not Implemented |
MZ0115 # 09 Y:2013 | 09 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,362 | $1,500 | Implemented |
OK0859 # 01 Y:2013 | 01 | 2013 | USE EXISTING DAM TO GENERATE ELECTRICITY | $12,404 | $65,000 | Not Implemented |
MZ0115 # 05 Y:2013 | 05 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,874 | $204,750 | Implemented |
MZ0115 # 10 Y:2013 | 10 | 2013 | CONDENSE OPERATION INTO ONE BUILDING | $99,466 | $35,000 | Implemented |
MZ0115 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,027 | $1,600 | Implemented |
MZ0115 # 06 Y:2013 | 06 | 2013 | USE PHOTOCELL CONTROLS | $2,832 | $750 | Not Implemented |
MZ0115 # 08 Y:2013 | 08 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,543 | $1,160 | Implemented |
MZ0115 # 04 Y:2013 | 04 | 2013 | ELIMINATE/REDUCE AN OPERATION | $11,784 | $0 | Implemented |
MZ0115 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $3,448 | $2,450 | Not Implemented |
AM0642 # 09 Y:2013 | 09 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $750 | $9 | Implemented |
AM0642 # 01 Y:2013 | 01 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,225 | $0 | Implemented |
AM0642 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,760 | $22,800 | Not Implemented |
AM0642 # 03 Y:2013 | 03 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,950 | $560 | Implemented |
AM0642 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,645 | $2,652 | Implemented |
AM0642 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,332 | $636 | Implemented |