505
matching recommendationsNAICS | 33392 | Material Handling Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0610 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $485 | $275 | Implemented |
AM0610 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $485 | $275 | Implemented |
TT0075 # 01 Y:2011 | 01 | 2011 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $36,083 | $42,000 | Not Implemented |
TT0075 # 02 Y:2011 | 02 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $109,802 | $50,000 | Not Implemented |
TT0075 # 03 Y:2011 | 03 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $47,625 | $21,000 | Implemented |
TT0075 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,202 | $14,000 | Implemented |
TT0075 # 05 Y:2011 | 05 | 2011 | INSTALL COMMON HEADER ON COMPRESSORS | $44,869 | $32,200 | Implemented |
TT0075 # 06 Y:2011 | 06 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,146 | $5,000 | Implemented |
TT0075 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,771 | $1,152 | Implemented |
TT0075 # 08 Y:2011 | 08 | 2011 | ISOLATE HOT OR COLD EQUIPMENT | $1,379 | $2,500 | Implemented |
TT0075 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,369 | $5,436 | Not Implemented |
TT0070 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,235 | $0 | Not Implemented |
TT0070 # 02 Y:2011 | 02 | 2011 | INSULATE BARE EQUIPMENT | $7,025 | $2,100 | Not Implemented |
TT0070 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $1,990 | $1,600 | Not Implemented |
TT0070 # 04 Y:2011 | 04 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $875 | $1,200 | Not Implemented |
TT0070 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,337 | $21,600 | Not Implemented |
TT0070 # 06 Y:2011 | 06 | 2011 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $1,730 | $4,900 | Not Implemented |
TT0070 # 07 Y:2011 | 07 | 2011 | OPTIMIZE PLANT POWER FACTOR | $6,582 | $32,600 | Not Implemented |
TT0070 # 08 Y:2011 | 08 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $11,486 | $102,000 | Not Implemented |
TT0070 # 09 Y:2011 | 09 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $5,985 | $1,347 | Not Implemented |
CO0645 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,890 | $1,290 | Implemented |
CO0645 # 02 Y:2011 | 02 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $630 | $3,010 | Not Implemented |
CO0645 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,950 | $33,510 | Implemented |
CO0645 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,930 | $5,260 | Not Implemented |
CO0645 # 05 Y:2011 | 05 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $2,000 | $21,500 | Not Implemented |