Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
36
matching recommendationsNAICS | 333923 | Overhead Traveling Crane, Hoist, and Monorail System Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1118 # 07 Y:2024 | 07 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,952 | $9,900 | n/a |
OK1118 # 06 Y:2024 | 06 | 2024 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,488 | $25,000 | n/a |
OK1118 # 05 Y:2024 | 05 | 2024 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $11,355 | $382,780 | n/a |
OK1118 # 04 Y:2024 | 04 | 2024 | OPTIMIZE PLANT POWER FACTOR | $816 | $4,683 | n/a |
OK1118 # 03 Y:2024 | 03 | 2024 | COMBINE UTILITY METERS | $453 | $2,200 | n/a |
OK1118 # 02 Y:2024 | 02 | 2024 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $772 | $450 | n/a |
OK1118 # 01 Y:2024 | 01 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $20,756 | $102,600 | n/a |
OK0903 # 03 Y:2015 | 03 | 2015 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $3,411 | $228 | Implemented |
OK0903 # 02 Y:2015 | 02 | 2015 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $96,611 | $20,611 | Implemented |
OK0903 # 04 Y:2015 | 04 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,633 | $30,000 | Implemented |
OK0903 # 05 Y:2015 | 05 | 2015 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $407 | $1,125 | Not Implemented |
OK0903 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,717 | $11,876 | Not Implemented |
OK0903 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $2,170 | $8,887 | Not Implemented |
OK0903 # 08 Y:2015 | 08 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,490 | $2,440 | Not Implemented |
OK0903 # 09 Y:2015 | 09 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,183 | $950 | Implemented |
OK0903 # 10 Y:2015 | 10 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,904 | $10,062 | Implemented |
OK0903 # 11 Y:2015 | 11 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,427 | $2,112 | Not Implemented |
OK0903 # 12 Y:2015 | 12 | 2015 | INSULATE BARE EQUIPMENT | $195 | $240 | Not Implemented |
OK0903 # 01 Y:2015 | 01 | 2015 | INSTALL SET-BACK TIMERS | $28,117 | $86 | Not Implemented |
OK0714 # 06 Y:2005 | 06 | 2005 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $70,215 | $3,931 | Not Implemented |
OK0714 # 05 Y:2005 | 05 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $10,600 | $0 | Implemented |
OK0714 # 04 Y:2005 | 04 | 2005 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,299 | $70 | Implemented |
OK0714 # 03 Y:2005 | 03 | 2005 | USE COMPRESSOR AIR FILTERS | $4,058 | $920 | Implemented |
OK0714 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $56,721 | $117,780 | Implemented |
OK0714 # 01 Y:2005 | 01 | 2005 | USE POWER DURING OFF-PEAK PERIODS | $1,866 | $0 | Not Implemented |