Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
87
matching recommendationsNAICS | 33399 | All Other General Purpose Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CW0126 # 01 Y:2022 | 01 | 2022 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $17,675 | $20,960 | n/a |
CW0126 # 02 Y:2022 | 02 | 2022 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $12,461 | $15,547 | n/a |
CW0126 # 03 Y:2022 | 03 | 2022 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $361 | $0 | n/a |
CW0126 # 04 Y:2022 | 04 | 2022 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $19,047 | $54,963 | n/a |
CW0126 # 05 Y:2022 | 05 | 2022 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $10,872 | $33,000 | n/a |
CW0126 # 06 Y:2022 | 06 | 2022 | USE POWER DURING OFF-PEAK PERIODS | $921 | $0 | n/a |
CW0126 # 07 Y:2022 | 07 | 2022 | USE SOLAR HEAT FOR HEAT | $2,171 | $13,500 | n/a |
WV0456 # 03 Y:2012 | 03 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,765 | $41,700 | Not Implemented |
WV0456 # 11 Y:2012 | 11 | 2012 | IMPROVE LUBRICATION PRACTICES | $1,660 | $1,000 | Implemented |
WV0456 # 09 Y:2012 | 09 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,207 | $5,050 | Not Implemented |
WV0456 # 16 Y:2012 | 16 | 2012 | USE PHOTOCELL CONTROLS | $824 | $705 | Implemented |
WV0456 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,729 | $12,395 | Implemented |
WV0456 # 05 Y:2012 | 05 | 2012 | IMPROVE COMBUSTION CONTROL CAPABILITY | $11,368 | $38,096 | Not Implemented |
WV0456 # 06 Y:2012 | 06 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,618 | $33,940 | Not Implemented |
WV0456 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $47,518 | $95,285 | Implemented |
WV0456 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,458 | $2,000 | Not Implemented |
WV0456 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,893 | $58,995 | Implemented |
WV0456 # 10 Y:2012 | 10 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,040 | $2,069 | Implemented |
WV0456 # 15 Y:2012 | 15 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,089 | $981 | Implemented |
WV0456 # 14 Y:2012 | 14 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,129 | $555 | Implemented |
WV0456 # 08 Y:2012 | 08 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,545 | $7,380 | Not Implemented |
WV0456 # 13 Y:2012 | 13 | 2012 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,180 | $1,000 | Implemented |
WV0456 # 12 Y:2012 | 12 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,637 | $2,475 | Implemented |
UD0793 # 02 Y:2009 | 02 | 2009 | INSULATE BARE EQUIPMENT | $6,677 | $1,000 | Implemented |
UD0793 # 03 Y:2009 | 03 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,960 | $500 | Not Implemented |