Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
94
matching recommendationsNAICS | 333996 | Fluid Power Pump and Motor Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0577 # 01 Y:2022 | 01 | 2022 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,354 | $640 | Implemented |
CO0742 # 01 Y:2021 | 01 | 2021 | USE SOLAR HEAT TO MAKE ELECTRICTY | $83,984 | $462,079 | Not Implemented |
CO0742 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,833 | $2,733 | Implemented |
CO0742 # 03 Y:2021 | 03 | 2021 | INSTALL OCCUPANCY SENSORS | $1,478 | $359 | Implemented |
CO0742 # 04 Y:2021 | 04 | 2021 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,318 | $16,143 | Implemented |
CO0742 # 05 Y:2021 | 05 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,499 | $200 | Not Implemented |
OK0823 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,696 | $22,166 | Not Implemented |
OK0823 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,396 | $2,500 | Not Implemented |
OK0823 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $922 | $2,975 | Implemented |
OK0823 # 04 Y:2012 | 04 | 2012 | INSULATE BARE EQUIPMENT | $5,300 | $16,148 | Implemented |
OK0823 # 05 Y:2012 | 05 | 2012 | USE HEAT PUMP FOR SPACE CONDITIONING | $139,115 | $1,292,500 | Not Implemented |
OK0815 # 09 Y:2011 | 09 | 2011 | INSULATE BARE EQUIPMENT | $3,531 | $633 | Implemented |
OK0815 # 01 Y:2011 | 01 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $57,281 | $13,000 | Not Implemented |
OK0815 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,341 | $930 | Implemented |
OK0815 # 08 Y:2011 | 08 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,335 | $20,544 | Not Implemented |
OK0815 # 07 Y:2011 | 07 | 2011 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $15,876 | $3,096 | Not Implemented |
OK0815 # 06 Y:2011 | 06 | 2011 | DISCONNECT BALLASTS | $849 | $696 | Not Implemented |
OK0815 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $2,608 | $2,198 | Not Implemented |
OK0815 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $340 | $950 | Implemented |
OK0815 # 02 Y:2011 | 02 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $12,351 | $0 | Implemented |
LE0260 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $67,607 | $74,000 | Not Implemented |
LE0260 # 02 Y:2007 | 02 | 2007 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $11,871 | $60 | Not Implemented |
LE0260 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,263 | $1,000 | Not Implemented |
LE0260 # 04 Y:2007 | 04 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,657 | $8,000 | Not Implemented |
LE0260 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $3,696 | $1,350 | Not Implemented |