IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

179

matching recommendations
Reset
NAICS 334 Computer and Electronic Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0779 # 11 Y:2008 11 2008 PAY BILLS ON TIME TO AVOID LATE FEES $4,322 $0 Implemented
UD0779 # 12 Y:2008 12 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,658 $1,000 Implemented
UD0779 # 13 Y:2008 13 2008 INSULATE BARE EQUIPMENT $1,228 $100 Implemented
UD0779 # 14 Y:2008 14 2008 COVER OPEN TANKS $537 $360 Implemented
UD0779 # 15 Y:2008 15 2008 RECOVER WASTE HEAT FROM EQUIPMENT $481 $2,000 Not Implemented
UD0713 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $84,867 $94,373 Not Implemented
UD0713 # 02 Y:2005 02 2005 USE OPTIMUM TEMPERATURE $64,754 $2,500 Not Implemented
UD0713 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,435 $41,783 Implemented
UD0713 # 04 Y:2005 04 2005 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $15,628 $3,900 Not Implemented
UD0713 # 05 Y:2005 05 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,868 $22,600 Not Implemented
UD0713 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,925 $200 Implemented
UD0713 # 07 Y:2005 07 2005 DEVELOP A REPAIR/REPLACE POLICY $1,021 $3,807 Implemented
UD0695 # 01 Y:2004 01 2004 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $42,439 $0 Not Implemented
UD0695 # 02 Y:2004 02 2004 AUTOMATE FINISHING PROCESS $14,454 $20,000 Not Implemented
UD0695 # 03 Y:2004 03 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $7,720 $0 Implemented
UD0695 # 04 Y:2004 04 2004 USE OPTIMUM TEMPERATURE $7,076 $9 Implemented
UD0695 # 05 Y:2004 05 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,056 $0 Implemented
UD0695 # 06 Y:2004 06 2004 ADVERTISE PRODUCT OR SERVICE $7,000 $-40,240 Implemented
UD0695 # 07 Y:2004 07 2004 OPTIMIZE PLANT POWER FACTOR $3,434 $0 Not Implemented
UD0695 # 08 Y:2004 08 2004 USE MINIMUM SAFE OVEN VENTILATION $2,564 $0 Implemented
UD0695 # 09 Y:2004 09 2004 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $2,331 $175 Implemented
UD0695 # 10 Y:2004 10 2004 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,110 $0 Implemented
UD0695 # 11 Y:2004 11 2004 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $784 $0 Implemented
UD0695 # 12 Y:2004 12 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $729 $0 Implemented
UD0695 # 13 Y:2004 13 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $397 $756 Implemented