Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
135
matching recommendationsNAICS | 33411 | Computer and Peripheral Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0104 # 05 Y:2013 | 05 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,600 | $100 | Not Implemented |
DL0104 # 06 Y:2013 | 06 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,500 | $100 | Not Implemented |
DL0104 # 07 Y:2013 | 07 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $9,800 | $100 | Not Implemented |
DL0104 # 08 Y:2013 | 08 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $34,300 | $9,570 | Not Implemented |
DL0104 # 09 Y:2013 | 09 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $30,500 | $700 | Not Implemented |
DL0104 # 10 Y:2013 | 10 | 2013 | MINIMIZE WATER USAGE | $5,100 | $280 | Not Implemented |
DL0104 # 11 Y:2013 | 11 | 2013 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $48,100 | $50,000 | Not Implemented |
DL0104 # 12 Y:2013 | 12 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $15,500 | $31,050 | Not Implemented |
DL0104 # 13 Y:2013 | 13 | 2013 | IMPROVE COMBUSTION CONTROL CAPABILITY | $10,200 | $3,800 | Not Implemented |
DL0104 # 14 Y:2013 | 14 | 2013 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $29,700 | $1,320 | Not Implemented |
DL0104 # 15 Y:2013 | 15 | 2013 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $18,800 | $45,000 | Not Implemented |
DL0104 # 16 Y:2013 | 16 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $22,505 | $10,700 | Not Implemented |
DL0104 # 17 Y:2013 | 17 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,800 | $37,400 | Not Implemented |
DL0104 # 18 Y:2013 | 18 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,900 | $45,000 | Not Implemented |
DL0104 # 19 Y:2013 | 19 | 2013 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $19,700 | $100 | Not Implemented |
SU0324 # 01 Y:2012 | 01 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,908 | $0 | Implemented |
SU0324 # 02 Y:2012 | 02 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,326 | $0 | Implemented |
SU0324 # 03 Y:2012 | 03 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $952 | $0 | Implemented |
SU0324 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $820 | $280 | Implemented |
SU0324 # 05 Y:2012 | 05 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,357 | $5,371 | Not Implemented |
SU0324 # 06 Y:2012 | 06 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $426 | $777 | Not Implemented |
SU0324 # 07 Y:2012 | 07 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,282 | $6,008 | Implemented |
SU0324 # 08 Y:2012 | 08 | 2012 | USE OTHER WASTE CONCENTRATION METHODS | $5,924 | $18,000 | Not Implemented |
MZ0023 # 01 Y:2008 | 01 | 2008 | INSULATE BARE EQUIPMENT | $183 | $80 | Implemented |
MZ0023 # 02 Y:2008 | 02 | 2008 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $5,828 | $2,077 | Not Implemented |