Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,581
matching recommendationsNAICS | 3344 | Semiconductor and Other Electronic Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0465 # 06 Y:2019 | 06 | 2019 | RECOVER MECHANICAL ENERGY | $4,582 | $20,880 | Not Implemented |
OK0991 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,462 | $17,053 | Implemented |
OK0991 # 02 Y:2018 | 02 | 2018 | OPTIMIZE PLANT POWER FACTOR | $7,248 | $14,404 | Not Implemented |
OK0991 # 03 Y:2018 | 03 | 2018 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,813 | $0 | Not Implemented |
OK0991 # 04 Y:2018 | 04 | 2018 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $5,577 | $1,015 | Implemented |
OK0991 # 05 Y:2018 | 05 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,710 | $536 | Implemented |
OK0991 # 06 Y:2018 | 06 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $724 | $0 | Implemented |
LE0464 # 01 Y:2018 | 01 | 2018 | TURN OFF EQUIPMENT WHEN NOT IN USE | $214 | $40 | Implemented |
LE0464 # 02 Y:2018 | 02 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $114 | $40 | Implemented |
LE0464 # 03 Y:2018 | 03 | 2018 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $10,836 | $28,000 | Implemented |
LE0464 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,809 | $23,000 | Implemented |
LE0464 # 05 Y:2018 | 05 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,187 | $12,000 | Implemented |
SF0528 # 01 Y:2018 | 01 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,402 | $11,547 | Not Implemented |
SF0528 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,330 | $22,874 | Implemented |
SF0528 # 03 Y:2018 | 03 | 2018 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,178 | $27,403 | Not Implemented |
MA0793 # 01 Y:2018 | 01 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $34,323 | $28,940 | Not Implemented |
MA0793 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,582 | $5,974 | Implemented |
MA0793 # 03 Y:2018 | 03 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $8,289 | $5,525 | Not Implemented |
MA0793 # 04 Y:2018 | 04 | 2018 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,522 | $1,000 | Not Implemented |
MA0793 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,012 | $500 | Implemented |
MA0793 # 06 Y:2018 | 06 | 2018 | REDUCE VENTILATION AIR | $419 | $1,000 | Not Implemented |
WM0124 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,040 | $13,392 | Not Implemented |
WM0124 # 02 Y:2018 | 02 | 2018 | PAY UTILITY BILLS ON TIME | $2,620 | $0 | Not Implemented |
WM0124 # 03 Y:2018 | 03 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,534 | $0 | Implemented |
WM0124 # 04 Y:2018 | 04 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,472 | $690 | Not Implemented |