Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
185
matching recommendationsNAICS | 3344 | Semiconductor and Other Electronic Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0076 # 04 Y:2004 | 04 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,277 | $0 | Implemented |
TA0076 # 01 Y:2004 | 01 | 2004 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $36,101 | $25,800 | Not Implemented |
TA0076 # 06 Y:2004 | 06 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,680 | $732 | Not Implemented |
TA0076 # 03 Y:2004 | 03 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $10,113 | $0 | Implemented |
TA0076 # 08 Y:2004 | 08 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $468 | $0 | Not Implemented |
TA0076 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $21,003 | $12,967 | Not Implemented |
TA0076 # 07 Y:2004 | 07 | 2004 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $880 | $0 | Not Implemented |
TA0076 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,001 | $720 | Implemented |
CO0552 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,570 | $620 | Implemented |
CO0552 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $950 | $2,800 | Not Implemented |
CO0552 # 07 Y:2004 | 07 | 2004 | RECOVER AND REUSE COOLING WATER | $4,170 | $20,000 | Not Implemented |
CO0552 # 06 Y:2004 | 06 | 2004 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $14,250 | $71,200 | Not Implemented |
CO0552 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,500 | $3,050 | Implemented |
CO0552 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,520 | $270 | Not Implemented |
CO0552 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $834 | $560 | Implemented |
CO0552 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $47,960 | $7,780 | Not Implemented |
SU0195 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,140 | $555 | Implemented |
SU0195 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,293 | $0 | Not Implemented |
SU0195 # 02 Y:2004 | 02 | 2004 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $333 | $0 | Not Implemented |
SU0195 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,236 | $1,380 | Implemented |
SU0195 # 04 Y:2004 | 04 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,836 | $1,837 | Implemented |
AS0390 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,953 | $23,750 | Not Implemented |
AS0390 # 05 Y:2004 | 05 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,779 | $197 | Implemented |
AS0390 # 04 Y:2004 | 04 | 2004 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $3,384 | $15,950 | Not Implemented |
AS0390 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,783 | $400 | Implemented |