Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
114
matching recommendationsNAICS | 33441 | Semiconductor and Other Electronic Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0515 # 04 Y:2006 | 04 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $29,840 | $13,000 | Not Implemented |
AM0515 # 05 Y:2006 | 05 | 2006 | MINIMIZE WATER USAGE | $24,580 | $15,000 | Not Implemented |
AM0515 # 06 Y:2006 | 06 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,500 | $6,700 | Implemented |
AM0515 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,580 | $27,400 | Implemented |
AM0515 # 08 Y:2006 | 08 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $6,900 | $80 | Implemented |
AM0515 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,560 | $20,750 | Not Implemented |
AM0515 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $4,440 | $1,580 | Implemented |
AM0515 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,690 | $3,800 | Not Implemented |
AM0514 # 01 Y:2006 | 01 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $189,400 | $50,000 | Implemented |
AM0514 # 02 Y:2006 | 02 | 2006 | USE SYNTHETIC LUBRICANT | $27,782 | $0 | Not Implemented |
AM0514 # 03 Y:2006 | 03 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,900 | $500 | Implemented |
AM0514 # 04 Y:2006 | 04 | 2006 | INSTALL OCCUPANCY SENSORS | $2,520 | $790 | Implemented |
AM0514 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,305 | $1,450 | Implemented |
AM0514 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $1,520 | $100 | Not Implemented |
AM0509 # 01 Y:2006 | 01 | 2006 | OPTIMIZE PLANT POWER FACTOR | $2,080 | $3,690 | Implemented |
AM0509 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $1,650 | $250 | Implemented |
AM0509 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,010 | $913 | Implemented |
AM0509 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $560 | $250 | Implemented |
AM0509 # 05 Y:2006 | 05 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $440 | $0 | Implemented |
TA0076 # 01 Y:2004 | 01 | 2004 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $36,101 | $25,800 | Not Implemented |
TA0076 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $21,003 | $12,967 | Not Implemented |
TA0076 # 03 Y:2004 | 03 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $10,113 | $0 | Implemented |
TA0076 # 04 Y:2004 | 04 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,277 | $0 | Implemented |
TA0076 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,001 | $720 | Implemented |
TA0076 # 06 Y:2004 | 06 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,680 | $732 | Not Implemented |