Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,581
matching recommendationsNAICS | 33441 | Semiconductor and Other Electronic Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0568 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $660 | $2,400 | Implemented |
CO0568 # 08 Y:2005 | 08 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $400 | $1,750 | Not Implemented |
CO0568 # 09 Y:2005 | 09 | 2005 | USE SOLAR HEAT TO HEAT WATER | $360 | $1,510 | Not Implemented |
SU0212 # 01 Y:2005 | 01 | 2005 | PAY BILLS ON TIME TO AVOID LATE FEES | $395 | $0 | Implemented |
SU0212 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,679 | $0 | Implemented |
SU0212 # 03 Y:2005 | 03 | 2005 | USE SYNTHETIC LUBRICANT | $375 | $0 | Implemented |
SU0212 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $670 | $0 | Not Implemented |
SU0212 # 05 Y:2005 | 05 | 2005 | INSTALL TURBULATORS | $985 | $571 | Not Implemented |
SU0212 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,637 | $1,889 | Implemented |
SU0212 # 07 Y:2005 | 07 | 2005 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $12,179 | $10,575 | Not Implemented |
SU0212 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $1,966 | $2,792 | Implemented |
SU0212 # 09 Y:2005 | 09 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $230 | $383 | Not Implemented |
SU0212 # 10 Y:2005 | 10 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $148 | $527 | Implemented |
SU0212 # 11 Y:2005 | 11 | 2005 | REDUCE VENTILATION AIR | $3,820 | $13,919 | Not Implemented |
SU0212 # 12 Y:2005 | 12 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $97,661 | $114,600 | Not Implemented |
SU0212 # 13 Y:2005 | 13 | 2005 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $21,189 | $111,859 | Not Implemented |
UF0361 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,815 | $9 | Implemented |
UF0361 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,264 | $1 | Implemented |
UF0361 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,324 | $2 | Implemented |
UF0361 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,002 | $2 | Implemented |
UF0361 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,934 | $0 | Implemented |
UF0361 # 06 Y:2005 | 06 | 2005 | RECYCLE FLUORESCENT LAMPS | $574 | $3 | Not Implemented |
LM0096 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,099 | $1,300 | Implemented |
LM0096 # 02 Y:2005 | 02 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $5,434 | $350 | Implemented |
LM0096 # 03 Y:2005 | 03 | 2005 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $91,510 | $125,000 | Not Implemented |