Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
126
matching recommendationsNAICS | 33441 | Semiconductor and Other Electronic Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0573 # 13 Y:2005 | 13 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $530 | $1,600 | Not Implemented |
CO0573 # 11 Y:2005 | 11 | 2005 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,340 | $0 | Implemented |
CO0570 # 07 Y:2005 | 07 | 2005 | INSTALL SKYLIGHTS | $3,180 | $19,200 | Not Implemented |
CO0570 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,270 | $210 | Implemented |
CO0570 # 02 Y:2005 | 02 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $280 | $420 | Implemented |
CO0570 # 03 Y:2005 | 03 | 2005 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,090 | $1,990 | Not Implemented |
CO0570 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $850 | $1,310 | Not Implemented |
CO0570 # 05 Y:2005 | 05 | 2005 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $680 | $340 | Implemented |
CO0570 # 06 Y:2005 | 06 | 2005 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $7,880 | $8,110 | Not Implemented |
CO0570 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,070 | $5,110 | Implemented |
CO0570 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $610 | $1,210 | Implemented |
SU0219 # 12 Y:2005 | 12 | 2005 | ADD AREA LIGHTING SWITCHES | $4,267 | $10,645 | Implemented |
SU0219 # 10 Y:2005 | 10 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $276 | $509 | Not Implemented |
SU0219 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $1,137 | $1,726 | Not Implemented |
SU0219 # 07 Y:2005 | 07 | 2005 | DISCONNECT BALLASTS | $6,107 | $5,363 | Implemented |
SU0219 # 11 Y:2005 | 11 | 2005 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $53,360 | $111,859 | Not Implemented |
SU0219 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $694 | $1,262 | Not Implemented |
SU0219 # 01 Y:2005 | 01 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,621 | $0 | Implemented |
SU0219 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,400 | $0 | Not Implemented |
SU0219 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,356 | $0 | Implemented |
SU0219 # 06 Y:2005 | 06 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $40,969 | $38,400 | Not Implemented |
SU0219 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,948 | $721 | Implemented |
SU0219 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $15,286 | $502 | Implemented |
SU0219 # 13 Y:2005 | 13 | 2005 | OPTIMIZE PLANT POWER FACTOR | $2,894 | $17,500 | Not Implemented |
CO0568 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,100 | $6,680 | Implemented |