Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
332
matching recommendationsNAICS | 334418 | Printed Circuit Assembly (Electronic Assembly) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BS0040 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $887 | $2,075 | Implemented |
BS0040 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $500 | $722 | Implemented |
BS0040 # 05 Y:2014 | 05 | 2014 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $316 | $464 | Not Implemented |
BS0040 # 06 Y:2014 | 06 | 2014 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $232 | $221 | Not Implemented |
BS0040 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $610 | $360 | Not Implemented |
BS0040 # 08 Y:2014 | 08 | 2014 | AIR CONDITION ONLY SPACE NECESSARY | $122 | $95 | Not Implemented |
BS0040 # 09 Y:2014 | 09 | 2014 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $51 | $119 | Not Implemented |
NC0504 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $686 | $25 | Not Implemented |
NC0504 # 02 Y:2013 | 02 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $333 | $50 | Implemented |
NC0504 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $103 | $100 | Implemented |
NC0504 # 04 Y:2013 | 04 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $363 | $850 | Not Implemented |
NC0504 # 05 Y:2013 | 05 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $618 | $300 | Implemented |
NC0504 # 06 Y:2013 | 06 | 2013 | INSTALL OCCUPANCY SENSORS | $1,428 | $2,892 | Implemented |
NC0504 # 07 Y:2013 | 07 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,341 | $21,429 | Implemented |
MA0715 # 01 Y:2013 | 01 | 2013 | BURN A LESS EXPENSIVE GRADE OF FUEL | $4,116 | $500 | Not Implemented |
MA0715 # 02 Y:2013 | 02 | 2013 | REDUCE VENTILATION AIR | $1,256 | $1,795 | Implemented |
MA0715 # 03 Y:2013 | 03 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $889 | $200 | Implemented |
MA0715 # 04 Y:2013 | 04 | 2013 | REDUCE VENTILATION AIR | $738 | $1,638 | Implemented |
MA0715 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $599 | $600 | Implemented |
MA0715 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $133 | $100 | Not Implemented |
IP0007 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,164 | $0 | Implemented |
IP0007 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,744 | $0 | Implemented |
IP0007 # 03 Y:2013 | 03 | 2013 | OPTIMIZE PLANT POWER FACTOR | $13,528 | $33,600 | Not Implemented |
IP0007 # 04 Y:2013 | 04 | 2013 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $46,311 | $151,951 | Not Implemented |
WM0012 # 01 Y:2012 | 01 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,304 | $1,675 | Not Implemented |