Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
34
matching recommendationsNAICS | 334418 | Printed Circuit Assembly (Electronic Assembly) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0012 # 07 Y:2012 | 07 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $62 | $128 | Implemented |
WM0012 # 06 Y:2012 | 06 | 2012 | AIR CONDITION ONLY SPACE NECESSARY | $597 | $975 | Not Implemented |
WM0012 # 05 Y:2012 | 05 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,779 | $4,500 | Not Implemented |
WM0012 # 04 Y:2012 | 04 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,999 | $5,230 | Implemented |
WM0012 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $771 | $100 | Not Implemented |
WM0012 # 02 Y:2012 | 02 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,345 | $375 | Not Implemented |
WM0012 # 01 Y:2012 | 01 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,304 | $1,675 | Not Implemented |
DL0096 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,429 | $30,095 | Implemented |
DL0096 # 02 Y:2012 | 02 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,176 | $8,000 | Implemented |
DL0096 # 03 Y:2012 | 03 | 2012 | KEEP EQUIPMENT CLEAN | $2,296 | $1,200 | Implemented |
DL0096 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,791 | $500 | Implemented |
DL0096 # 05 Y:2012 | 05 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $766 | $270 | Not Implemented |
MAS028 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $22,269 | $9,650 | Not Implemented |
MAS028 # 05 Y:2012 | 05 | 2012 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,762 | $5,000 | Implemented |
MAS028 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,781 | $0 | Not Implemented |
MAS028 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,815 | $4,000 | Implemented |
MAS028 # 01 Y:2012 | 01 | 2012 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $37,819 | $31,800 | Implemented |
MAS025 # 05 Y:2012 | 05 | 2012 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,171 | $4,300 | Implemented |
MAS025 # 04 Y:2012 | 04 | 2012 | INSULATE BARE EQUIPMENT | $5,622 | $935 | Not Implemented |
MAS025 # 03 Y:2012 | 03 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,097 | $0 | Not Implemented |
MAS025 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $11,105 | $10,770 | Not Implemented |
MAS025 # 01 Y:2012 | 01 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $50,701 | $22,000 | Not Implemented |
SU0317 # 01 Y:2012 | 01 | 2012 | CONDENSE OPERATION INTO ONE BUILDING | $333,000 | $6,675 | Implemented |
SU0317 # 02 Y:2012 | 02 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,105 | $270 | Not Implemented |
SU0317 # 03 Y:2012 | 03 | 2012 | REDUCE VENTILATION AIR | $9,899 | $14,092 | Implemented |