Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsNAICS | 334418 | Printed Circuit Assembly (Electronic Assembly) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0012 # 07 Y:2012 | 07 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $62 | $128 | Implemented |
WM0012 # 06 Y:2012 | 06 | 2012 | AIR CONDITION ONLY SPACE NECESSARY | $597 | $975 | Not Implemented |
WM0012 # 05 Y:2012 | 05 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,779 | $4,500 | Not Implemented |
WM0012 # 04 Y:2012 | 04 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,999 | $5,230 | Implemented |
WM0012 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $771 | $100 | Not Implemented |
WM0012 # 02 Y:2012 | 02 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,345 | $375 | Not Implemented |
WM0012 # 01 Y:2012 | 01 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,304 | $1,675 | Not Implemented |
DL0096 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,429 | $30,095 | Implemented |
DL0096 # 02 Y:2012 | 02 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,176 | $8,000 | Implemented |
DL0096 # 03 Y:2012 | 03 | 2012 | KEEP EQUIPMENT CLEAN | $2,296 | $1,200 | Implemented |
DL0096 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,791 | $500 | Implemented |
DL0096 # 05 Y:2012 | 05 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $766 | $270 | Not Implemented |
MAS028 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $22,269 | $9,650 | Not Implemented |
MAS028 # 05 Y:2012 | 05 | 2012 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,762 | $5,000 | Implemented |
MAS028 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,781 | $0 | Not Implemented |
MAS028 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,815 | $4,000 | Implemented |
MAS028 # 01 Y:2012 | 01 | 2012 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $37,819 | $31,800 | Implemented |
MAS025 # 05 Y:2012 | 05 | 2012 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,171 | $4,300 | Implemented |
MAS025 # 04 Y:2012 | 04 | 2012 | INSULATE BARE EQUIPMENT | $5,622 | $935 | Not Implemented |
MAS025 # 03 Y:2012 | 03 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,097 | $0 | Not Implemented |
MAS025 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $11,105 | $10,770 | Not Implemented |
MAS025 # 01 Y:2012 | 01 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $50,701 | $22,000 | Not Implemented |
SU0317 # 01 Y:2012 | 01 | 2012 | CONDENSE OPERATION INTO ONE BUILDING | $333,000 | $6,675 | Implemented |
SU0317 # 02 Y:2012 | 02 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,105 | $270 | Not Implemented |
SU0317 # 03 Y:2012 | 03 | 2012 | REDUCE VENTILATION AIR | $9,899 | $14,092 | Implemented |