Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,095
matching recommendationsNAICS | 335 | Electrical Equipment, Appliance, and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0185 # 07 Y:2004 | 07 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $363 | $288 | Not Implemented |
LL0185 # 08 Y:2004 | 08 | 2004 | USE PHOTOCELL CONTROLS | $101 | $56 | Not Implemented |
LL0185 # 09 Y:2004 | 09 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,500 | $60 | Implemented |
WV0289 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $46,305 | $117,949 | Not Implemented |
WV0289 # 02 Y:2004 | 02 | 2004 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $16,901 | $11,831 | Not Implemented |
WV0289 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,600 | $4,857 | Implemented |
WV0289 # 04 Y:2004 | 04 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $9,956 | $2,109 | Implemented |
WV0289 # 05 Y:2004 | 05 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,230 | $1,687 | Implemented |
WV0289 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,338 | $19,000 | Not Implemented |
WV0289 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,340 | $127 | Implemented |
WV0289 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $3,010 | $5,938 | Not Implemented |
WV0289 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,993 | $250 | Implemented |
WV0289 # 10 Y:2004 | 10 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,879 | $511 | Not Implemented |
WV0289 # 11 Y:2004 | 11 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,432 | $3,500 | Not Implemented |
WV0289 # 12 Y:2004 | 12 | 2004 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,170 | $103 | Implemented |
WV0289 # 13 Y:2004 | 13 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,628 | $1,119 | Not Implemented |
WV0289 # 14 Y:2004 | 14 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,227 | $1,631 | Implemented |
WV0289 # 15 Y:2004 | 15 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,365 | $0 | Implemented |
SD0335 # 01 Y:2004 | 01 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,899 | $8,001 | Not Implemented |
SD0335 # 02 Y:2004 | 02 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,194 | $80 | Not Implemented |
SD0335 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $857 | $0 | Implemented |
SD0335 # 04 Y:2004 | 04 | 2004 | REUSE RICH WHITE WATER IN OTHER APPLICATIONS | $10,570 | $14,000 | Not Implemented |
SD0335 # 05 Y:2004 | 05 | 2004 | REDESIGN PROCESS | $12,125 | $8,000 | Implemented |
MI0075 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,278 | $600 | Not Implemented |
MI0075 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,540 | $1,300 | Implemented |