Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsNAICS | 335 | Electrical Equipment, Appliance, and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MU0046 # 02 Y:2024 | 02 | 2024 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $7,422 | $9,923 | n/a |
MU0046 # 01 Y:2024 | 01 | 2024 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $465 | $484 | n/a |
MU0046 # 13 Y:2024 | 13 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $70,016 | $432,400 | n/a |
MU0046 # 12 Y:2024 | 12 | 2024 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,810 | $0 | n/a |
MU0046 # 11 Y:2024 | 11 | 2024 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,303 | $13,605 | n/a |
MU0046 # 10 Y:2024 | 10 | 2024 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $844 | $555 | n/a |
MU0046 # 09 Y:2024 | 09 | 2024 | USE PHOTOCELL CONTROLS | $74 | $706 | n/a |
MU0046 # 08 Y:2024 | 08 | 2024 | TURN OFF EQUIPMENT WHEN NOT IN USE | $426 | $0 | n/a |
MU0046 # 07 Y:2024 | 07 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $320 | $1,932 | n/a |
MU0046 # 06 Y:2024 | 06 | 2024 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $814 | $0 | n/a |
MU0046 # 05 Y:2024 | 05 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $160 | $17 | n/a |
MU0046 # 04 Y:2024 | 04 | 2024 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $340 | $2,498 | n/a |
MU0046 # 03 Y:2024 | 03 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,153 | $0 | n/a |
MU0007 # 01 Y:2022 | 01 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,417 | $10,160 | Implemented |
MU0007 # 02 Y:2022 | 02 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,200 | $7,825 | Not Implemented |
MU0007 # 04 Y:2022 | 04 | 2022 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,004 | $0 | Implemented |
MU0007 # 06 Y:2022 | 06 | 2022 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $12 | $44 | Implemented |
MU0007 # 05 Y:2022 | 05 | 2022 | INSTALL SET-BACK TIMERS | $612 | $541 | Not Implemented |
MU0007 # 03 Y:2022 | 03 | 2022 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,914 | $0 | Implemented |
UM0487 # 03 Y:2017 | 03 | 2017 | COVER OPEN TANKS | $23,071 | $2,137 | n/a |
UM0487 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $42,701 | $105,530 | n/a |
UM0487 # 01 Y:2017 | 01 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,265 | $4,500 | n/a |
IC0149 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $1,470 | $7,381 | Implemented |
IC0149 # 07 Y:2008 | 07 | 2008 | UPGRADE OBSOLETE EQUIPMENT | $19,706 | $210 | Implemented |
IC0149 # 08 Y:2008 | 08 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $37,783 | $29,280 | Implemented |