Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

102

matching recommendations
Reset
NAICS 3352 Household Appliance Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0712 # 03 Y:2005 03 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $8,212 $22,500 Not Implemented
UD0712 # 04 Y:2005 04 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,955 $20,660 Not Implemented
UD0712 # 05 Y:2005 05 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,839 $839 Implemented
UD0712 # 06 Y:2005 06 2005 $2,256 $0 Not Implemented
UD0712 # 07 Y:2005 07 2005 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,166 $525 Implemented
UD0712 # 08 Y:2005 08 2005 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,616 $1,000 Not Implemented
UD0712 # 09 Y:2005 09 2005 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,498 $0 Not Implemented
UD0712 # 10 Y:2005 10 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $953 $0 Not Implemented
UD0712 # 11 Y:2005 11 2005 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $259 $1,000 Implemented
SD0335 # 01 Y:2004 01 2004 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,899 $8,001 Not Implemented
SD0335 # 02 Y:2004 02 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,194 $80 Not Implemented
SD0335 # 03 Y:2004 03 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $857 $0 Implemented
SD0335 # 04 Y:2004 04 2004 REUSE RICH WHITE WATER IN OTHER APPLICATIONS $10,570 $14,000 Not Implemented
SD0335 # 05 Y:2004 05 2004 REDESIGN PROCESS $12,125 $8,000 Implemented
UD0677 # 01 Y:2003 01 2003 $34,103 $28,000 Not Implemented
UD0677 # 02 Y:2003 02 2003 INSTALL TIMERS AND/OR THERMOSTATS $21,861 $489 Not Implemented
UD0677 # 03 Y:2003 03 2003 REUSE / RECYCLE/ SELL PAPER PRODUCTS $18,425 $0 Implemented
UD0677 # 04 Y:2003 04 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $20,186 $72,000 Not Implemented
UD0677 # 05 Y:2003 05 2003 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $17,000 $20,000 Implemented
UD0677 # 06 Y:2003 06 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,580 $53,130 Implemented
UD0677 # 07 Y:2003 07 2003 DISCONNECT BALLASTS $3,557 $297 Not Implemented
UD0677 # 08 Y:2003 08 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,700 $470 Implemented
UD0677 # 09 Y:2003 09 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,135 $400 Implemented
UD0677 # 10 Y:2003 10 2003 INSULATE BARE EQUIPMENT $1,019 $252 Not Implemented
UD0677 # 11 Y:2003 11 2003 INSULATE BARE EQUIPMENT $737 $200 Implemented