IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

35

matching recommendations
Reset
NAICS 335314 Relay and Industrial Control Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0483 # 11 Y:2016 11 2016 INSTALL OCCUPANCY SENSORS $243 $600 Not Implemented
BD0483 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,053 $10,965 Not Implemented
BD0483 # 02 Y:2016 02 2016 USE RADIANT HEATER FOR SPOT HEATING $4,162 $8,800 Not Implemented
BD0483 # 01 Y:2016 01 2016 INSULATE BARE EQUIPMENT $7,762 $1,810 Not Implemented
BD0483 # 04 Y:2016 04 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,476 $15 Not Implemented
BD0483 # 05 Y:2016 05 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,361 $9,836 Not Implemented
BD0483 # 06 Y:2016 06 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,961 $1,500 Not Implemented
BD0483 # 07 Y:2016 07 2016 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,172 $576 Not Implemented
BD0483 # 08 Y:2016 08 2016 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,074 $50 Not Implemented
BD0483 # 09 Y:2016 09 2016 INSTALL OCCUPANCY SENSORS $469 $600 Not Implemented
BD0483 # 10 Y:2016 10 2016 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $286 $320 Not Implemented
BD0421 # 01 Y:2013 01 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,364 $30,195 Implemented
BD0421 # 02 Y:2013 02 2013 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $12,995 $1,140 Not Implemented
BD0421 # 03 Y:2013 03 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $11,571 $15,000 Implemented
BD0421 # 04 Y:2013 04 2013 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $4,147 $1,500 Not Implemented
BD0421 # 05 Y:2013 05 2013 INSTALL OCCUPANCY SENSORS $6,067 $1,425 Implemented
BD0421 # 06 Y:2013 06 2013 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $5,564 $40 Not Implemented
BD0421 # 07 Y:2013 07 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,968 $1,500 Implemented
BD0421 # 08 Y:2013 08 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,219 $2,000 Not Implemented
BD0421 # 09 Y:2013 09 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $759 $700 Implemented
BD0421 # 10 Y:2013 10 2013 MINIMIZE WATER USAGE $4,683 $4,200 Implemented
BD0410 # 02 Y:2012 02 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $11,850 $20 Not Implemented
BD0410 # 09 Y:2012 09 2012 INSTALL AUTOMATIC STACK DAMPER $1,223 $1,750 Not Implemented
BD0410 # 08 Y:2012 08 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,907 $500 Not Implemented
BD0410 # 07 Y:2012 07 2012 INSTALL OCCUPANCY SENSORS $2,094 $2,025 Not Implemented