Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,067

matching recommendations
Reset
NAICS 3359 Other Electrical Equipment and Component Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0355 # 07 Y:2010 07 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $290 $595 Not Implemented
MS0369 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,176 $38,740 Not Implemented
MS0369 # 02 Y:2010 02 2010 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $10,766 $6,978 Not Implemented
MS0369 # 03 Y:2010 03 2010 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $7,079 $32,037 Not Implemented
MS0369 # 04 Y:2010 04 2010 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,377 $59,145 Not Implemented
OK0788 # 01 Y:2010 01 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $285 $451 Implemented
OK0788 # 02 Y:2010 02 2010 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $29,667 $2,587 Not Implemented
OK0788 # 03 Y:2010 03 2010 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,568 $1,078 Not Implemented
OK0788 # 04 Y:2010 04 2010 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $3,625 $1,176 Implemented
OK0788 # 05 Y:2010 05 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,103 $5,543 Not Implemented
OK0788 # 06 Y:2010 06 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,350 $8,818 Implemented
OK0788 # 07 Y:2010 07 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35,265 $98,109 Implemented
OK0788 # 08 Y:2010 08 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $441 $1,170 Not Implemented
OK0788 # 09 Y:2010 09 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,877 $0 Not Implemented
OK0788 # 10 Y:2010 10 2010 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $15,837 $12,000 Implemented
OK0788 # 11 Y:2010 11 2010 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $6,106 $101,906 Not Implemented
OK0788 # 12 Y:2010 12 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $22,393 $7,656 Not Implemented
SF0370 # 01 Y:2009 01 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $316 $0 Not Implemented
SF0370 # 02 Y:2009 02 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,936 $2,464 Not Implemented
SF0370 # 03 Y:2009 03 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $684 $849 Not Implemented
SF0370 # 04 Y:2009 04 2009 INSULATE BARE EQUIPMENT $942 $2,473 Not Implemented
SF0370 # 05 Y:2009 05 2009 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $972 $2,956 Not Implemented
SF0370 # 06 Y:2009 06 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $1,614 $7,537 Not Implemented
SF0370 # 07 Y:2009 07 2009 INSTALL OCCUPANCY SENSORS $1,231 $10,326 Not Implemented
SF0370 # 08 Y:2009 08 2009 USE SOLAR HEAT TO MAKE ELECTRICTY $74,612 $654,810 Not Implemented