Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
87
matching recommendationsNAICS | 3359 | Other Electrical Equipment and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0426 # 04 Y:2013 | 04 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,301 | $7,526 | Not Implemented |
SF0426 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $373 | $1,619 | Not Implemented |
SF0426 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,979 | $17,191 | Implemented |
SF0370 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $1,231 | $10,326 | Not Implemented |
SF0370 # 08 Y:2009 | 08 | 2009 | USE SOLAR HEAT TO MAKE ELECTRICTY | $74,612 | $654,810 | Not Implemented |
SF0370 # 06 Y:2009 | 06 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,614 | $7,537 | Not Implemented |
SF0370 # 05 Y:2009 | 05 | 2009 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $972 | $2,956 | Not Implemented |
SF0370 # 04 Y:2009 | 04 | 2009 | INSULATE BARE EQUIPMENT | $942 | $2,473 | Not Implemented |
SF0370 # 03 Y:2009 | 03 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $684 | $849 | Not Implemented |
SF0370 # 01 Y:2009 | 01 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $316 | $0 | Not Implemented |
SF0370 # 02 Y:2009 | 02 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,936 | $2,464 | Not Implemented |
LM0109 # 01 Y:2006 | 01 | 2006 | USE POWER DURING OFF-PEAK PERIODS | $65,901 | $200,000 | Implemented |
LM0109 # 02 Y:2006 | 02 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $408 | $586 | Implemented |
LM0109 # 03 Y:2006 | 03 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $13,210 | $90,000 | Implemented |
LM0109 # 04 Y:2006 | 04 | 2006 | AUTOMATE FINISHING PROCESS | $240,621 | $225,000 | Not Implemented |
LM0109 # 05 Y:2006 | 05 | 2006 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $220,603 | $170,000 | Not Implemented |
LM0109 # 06 Y:2006 | 06 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $14,573 | $120,000 | Implemented |
LM0109 # 07 Y:2006 | 07 | 2006 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $8,917 | $7,000 | Implemented |
LM0110 # 06 Y:2006 | 06 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $153,608 | $23,700 | Implemented |
LM0110 # 05 Y:2006 | 05 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $193,195 | $15,800 | Not Implemented |
LM0110 # 04 Y:2006 | 04 | 2006 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $85,569 | $90,000 | Not Implemented |
LM0110 # 02 Y:2006 | 02 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,085 | $5,844 | Not Implemented |
LM0110 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,799 | $90,000 | Implemented |
LM0110 # 03 Y:2006 | 03 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $116,775 | $100,000 | Not Implemented |
LM0058 # 01 Y:2003 | 01 | 2003 | ADD AREA LIGHTING SWITCHES | $6,786 | $7,274 | Implemented |